   PORTABLE REFRIGERATED SLIMLINE AIR CONDITIONER - CP12CW3

  

  |   

4

Don’t use extension pieces for the 
exhaust hose as this will reduce 
performance and possibly result in 
damage to the air conditioner.

Hot air and mist will be emitted outside 
through the exhaust hose. It is critical to 
the performance of the unit that all of the 
exhaust air is removed from the space 
being cooled.

Installing a Drain Hose

For continuous draining of water during 
dehumidifying mode operation.

Step 1:

 Remove the drain outlet plug at 

the bottom rear of the air conditioner. 

Step 2:

 Connect a 12 mm diameter hose 

to the drain outlet as shown in Figure 7. 

Push on fi rmly to secure into place. 

Positioning

Place the air conditioner on a fi rm, fl at 
surface. The minimum distance required 
from the operating air conditioner to any 
walls or objects is 50 cm.

Installing the Exhaust Hose
Step 1:

 Fit the hose end connectors to 

the exhaust hose by turning the hose 
end connectors counter-clock-wise to the 
exhaust hose as shown in Figure 5.

Step 2:

 Open a window and fi t the 

window kit. Extend the attachments as 
required and lock into place with the 
window kit screw provided. Ensure the 
outlet is not obstructed. The window kit 
can be installed horizontally or vertically, 
to suit your window type. 

Step 3:

 Fit the hose end connector to the 

window kit, and lock into place with one of 
the screws provided. 

Step 4:

 Lead the other end of the 

exhaust hose onto the exhaust outlet at 
the rear of the air conditioner as shown 
in Figure 6. Ensure the clips on the air 
conditioner have engaged onto the hose 
end connector. Keep the exhaust hose as 
short and straight as possible. This will 
maximise the cooling performance. 

INSTALLATION

7

5

6

Clips

Step 3:

 Run the free end of the pipe to a 

drain. Make sure that the drain hose does 
not rise above the drain outlet as the 
water will not fl ow otherwise.

In window

Summary of Contents for CP12CW3

Page 1: ...OWNER S MANUAL Supercool Portable Refrigerated Slimline Air Conditioner English CP12CW3...

Page 2: ...isposed of with household waste This product should be taken to your local recycling centre for safe treatment CONTENTS Introduction 1 Safety 2 Component Location 3 Installation 4 Control and Display...

Page 3: ...sure the appliance has been securely and correctly installed according to the installation instructions contained within this manual Personal Cooling Your Convair refrigerated air conditioner is a po...

Page 4: ...accordance with national wiring regulations Electrical Safety cont Caution Before connecting the electrical power cord to a power outlet check that the air conditioner voltage as shown on the rating l...

Page 5: ...ust outlet 9 Power supply cord 10 Cord storage 11 Water tank drain 12 Condenser air intake 13 Air lters 14 Handle 15 Remote control storage 16 Window kit 3 screws included 17 Exhaust hose 18 Hose end...

Page 6: ...ng the Exhaust Hose Step 1 Fit the hose end connectors to the exhaust hose by turning the hose end connectors counter clock wise to the exhaust hose as shown in Figure 5 Step 2 Open a window and t the...

Page 7: ...y Saving CONTROL AND DISPLAY 8 Air Conditioner Control Panel 1 10 12 11 6 7 5 2 8 3 4 6 4 13 5 9 Air Conditioner Remote Controller 3 1 2 3 7 9 8 9 COOL mode DEHUMIDIFY mode FAN mode ENERGY SAVINGS mod...

Page 8: ...n range 6 metres of the air conditioner Note If there are two of the same air conditioners installed they cannot be controlled separately When you operate either remote it will turn on both air condit...

Page 9: ...adjust the fan speeds Note In cooling mode the fan will continue to operate even if the compressor has turned off Note In dehumidifying mode the fan speed is locked at low and the temperature cannot...

Page 10: ...the air conditioner after a set period of time Timer for automatic start up is set by following the below steps with the air conditioner in stand by mode Timer for automatic shut down is set with the...

Page 11: ...C 3 Dry thoroughly before replacing 4 Take care to replace the lter back into the slot in the cooler Note Never operate the air conditioner without the lters MAINTENANCE Draining the air conditioner P...

Page 12: ...ath the air conditioner uneven The remote control does not work Is there anything obstructing the remote signal receiver Ensure to aim the remote at the air conditioner Ensure you are with the remote...

Page 13: ...r 430 Moisture Removal L hr 1 4 Refrigerant type Charge R410A 560g Max Pressure Suction MPa 2 0 Max Pressure Discharge MPa 5 0 Ingress Protection IPX0 Weight kg 34 0 Dimensions mm W 471 x D 355 x H 85...

Page 14: ...o misuse of the appliance Normal user maintenance Setting of controls Transit damage or Damage caused by user misuse tampering or failure to observe the care and special provisions in the instructions...

Page 15: ...al com PRIVACY NOTICE Seeley International Pty Ltd ABN 23 054 687 035 will use the personal information you provide us with to provide warranty support for the product you have purchased and to inform...

Page 16: ...leyinternational com It is the policy of Seeley International to introduce continual product improvement Accordingly speci cations are subject to change without notice Please consult with your dealer...

Reviews: