Installation distance to walls and ceiling
*If the wood compartment is to be placed between the surround and the wall at least 465 / 610 mm is required.
C21
1755
2305
Min 2380
475
670
950
Combustible roof
265
120
1595
1965 ±20
(1430)
620
1390
Utv. Ø 200
400*
265
875
The dimension diagrams only show the minimum
permitted installation distances for the insert. When
connecting to a steel flue, also note the safety distance
requirements of the flue. The safety distance between an
uninsulated flue and a combustible part of the building
should be at least 300 mm. The minimum distance to
combustible parts of the building or interior decoration in
front of the insert must be at least 1.5 m.
Important!
INSTALLATION DISTANCES