Installation distance to walls and ceiling
1620
Min 2380
2305
475
450
1050
Combustible roof
265
120
1375
(1210)
1170
620
1880 ±60
Utv. Ø 200
400*
265
925
*If the wood compartment is to be placed between the surround and the wall at least 465 / 610 mm is required.
C11
The dimension diagrams only show the minimum
permitted installation distances for the insert. When
connecting to a steel flue, also note the safety distance
requirements of the flue. The safety distance between an
uninsulated flue and a combustible part of the building
should be at least 300 mm. The minimum distance to
combustible parts of the building or interior decoration in
front of the insert must be at least 1.5 m.
Important!
INSTALLATION DISTANCES