The gap between the concrete and the wall behind can be
grouted if so desired. It is important that the air inlet,
100x15 mm, at the bottom of the section two is not
blocked if the integrated protective screen is installed. If
the surround is installed against a normal firewall the air
intake can be blocked if so desired.
When the paint is dry the grilles can be installed. The top
grilles* are placed in position on the upper side, and the
lower grille pins are installed using the springs and lugs
supplied.
* (not used when installing the height extension section).
Even off the edges between the concrete blocks by applying a
little grout in the joints and then using the corner of a filling
knife to scrape out the excess and retain the marked edges.
Fill and sand small scratches and pores in the concrete.
As soon as the silicone, grout and any repairs to the concrete
are dry the surround can be painted with a silicate paint.
ASSEMBLY