background image

5

SOLO - Programming

Step 6: Program the SOLO 

ENROL MASTER CARD

The Master Card is used to access all the programming functions of the SOLO.

Warning: When enrolling the Master Card, the controller will be reset to its 

factory default condition and ALL USERS WILL BE PERMANENTLY REMOVED 

FROM MEMORY. It is important, therefore, that you enrol the Master Card 

before doing anything else.

Press and hold the S2 button, then press and hold the  

S1 button at the same time.  When the controller  

beeps 3 times, release both buttons and the display will show  

This indicates that the SOLO is now in ‘Enrol Master Card’ mode. Hold the Master 

Card supplied against a reader until the controller beeps 3 times.  The controller has 

now enrolled the Master Card, ended the enrolment mode and is ready for normal 

operation.

NOTE: 

When pressing S2 and S1, if the display shows 

  t 1

, release both buttons 

and wait 30 seconds for the display to clear, then try again. 

ENROL USERS

Present the Master Card to a reader for approximately 5 seconds until the controller 

beeps once and then three times. This signifies the ‘Enrol User’ 

 

mode.  The controller displays a single dot in the centre of the display 

Remove the Master Card and present a new user card until the controller beeps once, 

indicating that it has enrolled the card. 

Keep presenting new cards to enrol them until all the required user cards have been 

enrolled (999 total). If presenting a card causes the controller to beep three times, 

no more cards can be enrolled.

The controller will exit this mode after 30 seconds of inactivity, indicated by 3 beeps.

In the normal operating mode, pressing button S2 will display the number of the last 
card used (e.g. 

0 1 6

 for user 16).

It is important to keep a record of who has which card and the relevant user 

number, as it may be necessary to remove the user from the system in the 

future. A table has been provided at the end of this manual to record this 

information.

Summary of Contents for SOLO CS-AC-3210

Page 1: ...s Power 12V to 24V ac or dc Current 100mA 12V with 1 reader head Readers One or two compatible reader heads CS AC 3211 Mullion CS AC 3212 Vandal Resistant or CS AC 3213 Panel Mount Inputs Normally Ope...

Page 2: ...oller for 1 reader head To use two reader heads remove the jumper and fit it across both pins as shown NOTE If this jumper is not in the correct position the system may experience seemingly random or...

Page 3: ...blocks 1 and 8 The Fire Alarm Panel must provide voltage free normally open contacts Step 5 Connect Outputs The SOLO has two relay outputs one for the electric door lock and the other for an alarm si...

Page 4: ...eakglass applies power to the door strike to ensure that the door is released in an emergency ALWAYS fit a MOV across the coil of the door strike to prevent Back EMF from damaging the SOLO Siren Use t...

Page 5: ...buttons and wait 30 seconds for the display to clear then try again ENROL USERS Present the Master Card to a reader for approximately 5 seconds until the controller beeps once and then three times Thi...

Page 6: ...lt up to 4 minutes 30 seconds in intervals of 30 seconds Program Timers Press and release button S1 The display will show t 1 This indicates the default Door Release Time of 1 second Press and release...

Page 7: ...0 0 1 Repeatedly press S1 until required user number shown Press and hold S2 beep Door Release Time Door Open Alarm Duration Press S1 t 1 1 second Default Press S1 t 2 2 seconds etc up to Press S1 t 9...

Page 8: ...e feel free to photocopy this page to record further users SOLO User List Controlsoft UK 44 0 1451 844896 support controlsoft com controlsoft uk support Information on all our products can be found on...

Reviews: