![Controlsoft SOLO CS-AC-3210 Installation Instructions Manual Download Page 6](http://html1.mh-extra.com/html/controlsoft/solo-cs-ac-3210/solo-cs-ac-3210_installation-instructions-manual_2658965006.webp)
6
SOLO - Programming
REMOVE USERS
To remove one or more users, present the Master Card to a reader until the controller
beeps once and then three times.
Press and hold button S1 and the display will show the user number
0 0 1
Repeatedly press button S1 to step up through the user numbers, or hold it down to
scroll faster. Release the button when the required user number is displayed.
Press button S2, the controller beeps and the number changes to
- - -
. The
selected user has now been removed from the memory
The SOLO has 2 timers for door control as described below:
DOOR RELEASE TIME
This is the duration that the door remains unlocked following presentation of a valid
card. This duration can be adjusted from 1 seconds (default) up to 9 seconds in
intervals of 1 second.
DOOR OPEN ALARM DURATION
If a door contact is fitted and the door is left open for too long, the controller can
generate an alarm condition and activate the siren. This duration can be adjusted
from 30 seconds (default) up to 4 minutes 30 seconds in intervals of 30 seconds.
Program Timers
Press and release button S1. The display will show
t 1
. This indicates the default
Door Release Time of 1 second.
Press and release button S1 again to increment the setting to
t 2
(2 seconds).
Continue to the maximum setting of
t 9
(9 seconds).
NOTE: The display
t -
indicates a special operating mode for interfacing to other
equipment, whereby the door relay is pulsed for 150ms.
When the desired time is shown on the display, either progress to the Door Open
Alarm Duration (see below), or end programming mode by leaving the controller until
it beeps 3 times and the display clears.
To program the Door Open Alarm Duration, press and release button S2 and the
display changes to
A 1
. This indicates the default duration of 30 seconds.
Press button S2 to increment the setting to
A 2
(1 minute).
Continue to press S2 up to the maximum setting of
A 9
(4 minutes 30 seconds).
When the desired Door Open Alarm Duration is shown on the display, end
programming mode by leaving the controller until it beeps 3 times and the display
clears.
Important!
A door open alarm can only be generated if a door contact is fitted to the
system.