Programming Summary

Enrol Master Card

Enrolling a Master Card resets the 

controller back to Factory Defaults 

and deletes all users

Press and hold the S2 button, then press 

and hold the S1 button at the same time.

Beep beep beep

    

Release both buttons and display will 

show: 

Present Master Card to reader.

Enrol Users

Present Master Card to reader for ~ 5 

seconds 

Beep,   beep beep beep

  

Present new card  

beep

  

Present another new card  

beep

Present another new card  

beep

  etc

Remove Users

Present Master Card to reader  for ~ 5 

seconds  

Beep,   beep beep beep

Press & hold S1  

beep beep beep 

 

0 0 1

Repeatedly press S1 until required user 

number shown
Press and hold S2  

beep

   

- - -

Door Release Time

Door Open Alarm  

Duration

Press S1 

  t 1

 = 1 second (Default)

Press S1 

  t 2

 = 2 seconds etc. up to

Press S1 

  t 9

 

= 9 seconds

Press S2 

  A 1

 = 30 seconds (Default)

Press S2 

  A 2

 = 1 minute etc. up to

Press S2 

  A 9

 = 4 minutes 30 seconds

View user number for any card

In normal operating mode, present card 

to reader to open door, user number is 

briefly shown on the display.  

 

Press button S2 to view number of last 

card used.

IMPORTANT

If you lose your Master Card, learning a new one will reset the  

SOLO to its factory default condition, and  

ALL USERS WILL BE DELETED

.   

Please record  the number of your Master Card below, to allow a  

replacement to be ordered if the original is lost:

SOLO - Programming Guide

Summary of Contents for SOLO CS-AC-3210

Page 1: ...s Power 12V to 24V ac or dc Current 100mA 12V with 1 reader head Readers One or two compatible reader heads CS AC 3211 Mullion CS AC 3212 Vandal Resistant or CS AC 3213 Panel Mount Inputs Normally Ope...

Page 2: ...oller for 1 reader head To use two reader heads remove the jumper and fit it across both pins as shown NOTE If this jumper is not in the correct position the system may experience seemingly random or...

Page 3: ...blocks 1 and 8 The Fire Alarm Panel must provide voltage free normally open contacts Step 5 Connect Outputs The SOLO has two relay outputs one for the electric door lock and the other for an alarm si...

Page 4: ...eakglass applies power to the door strike to ensure that the door is released in an emergency ALWAYS fit a MOV across the coil of the door strike to prevent Back EMF from damaging the SOLO Siren Use t...

Page 5: ...buttons and wait 30 seconds for the display to clear then try again ENROL USERS Present the Master Card to a reader for approximately 5 seconds until the controller beeps once and then three times Thi...

Page 6: ...lt up to 4 minutes 30 seconds in intervals of 30 seconds Program Timers Press and release button S1 The display will show t 1 This indicates the default Door Release Time of 1 second Press and release...

Page 7: ...0 0 1 Repeatedly press S1 until required user number shown Press and hold S2 beep Door Release Time Door Open Alarm Duration Press S1 t 1 1 second Default Press S1 t 2 2 seconds etc up to Press S1 t 9...

Page 8: ...e feel free to photocopy this page to record further users SOLO User List Controlsoft UK 44 0 1451 844896 support controlsoft com controlsoft uk support Information on all our products can be found on...

Reviews: