PRODUCT INSTALLATION CONTINUED

4.  Remove Top Cover To Control Panel:  IMPORTANT:  First make sure power supply is unplugged from 

power source.

  Then remove the top cover of the control panel by unfastening the 4 screws as shown in the 

picture below allowing the top cover to freely separate from the bottom section of the control panel.  

5.  Fasten Bottom Section Of Control Panel To Skirting:

  Locate the two fastening holes as shown in the pic

-

ture below.  Use the supplied screws to securely fasten the bottom section of the control panel to the skirting.

6.  Fasten Top Cover of Control Panel:

  Make sure the black rubber gasket is secured in the grove on un-

derside of the top cover.  Replace the top cover of the control panel and securely tighten the 4 panel cover 

screws.    

WARNING:  Do not remove power cable or cell cable from the connectors inside the control 

panel.  Should cables become disconnected, make sure they are reconnected with the correct polar-

ity.  Reversing will damage the control panel.

Unfasten Screws

Unfasten Screws

Watertight Cable Grips

Fastening Holes

Fastening Holes

Summary of Contents for ChlorMaker IL

Page 1: ...ControlOMatic Inc 12659 Arbor Lane Grass Valley CA 95949 www ControlOMatic com Support ControlOMatic com 530 205 4520 Manual Version 2 1 14 Made in the USA ChlorMaker IL TM OPERATING INSTRUCTIONS...

Page 2: ...otected VAC power source only WARNING Protect the power supply and outlet from exposure to the elements including direct sun rain snow condensation etc WARNING DO NOT use with extension cord Injury ma...

Page 3: ...er chemistry for portable spas PARAMETER RECOMMENDED LEVEL Free Chlorine 3 0 to 5 0 PPM PH Balance 7 2 to 7 6 Total Alkalinity 80 to 120 PPM Calcium Hardness 300 to 400 PPM It is recommended that chlo...

Page 4: ...he volume of water in gallons or liters by checking the spa owner s manual or use any internet volume calculator 99 Pure Sodium Chloride NaCl Coarse Grain Example For a 350 Gallon Spa Divide 350 Gal b...

Page 5: ...control panel to the power source The black cable clips can be used to secure the cable in place IMPORTANT Make sure the power source is GFI Protected and is protected by a weather protec tive cover S...

Page 6: ...ure below Use the supplied screws to securely fasten the bottom section of the control panel to the skirting 6 Fasten Top Cover of Control Panel Make sure the black rubber gasket is secured in the gro...

Page 7: ...agram below Item A Cell Orientation The cell must be mounted relatively vertical to prevent chlorine gas from being trapped in the cell 9 Connect Tubing To Cell Cut the existing tube and reconnect the...

Page 8: ...is important to re set the power level down several levels If usage significantly increases return from vacation etc it is important to adjust the power level up accordingly Always retest and adjust t...

Page 9: ...ghts Salt level may be too high and engaged the automat ic shut down feature Dilute the spa water by draining some of the spa water and refilling with fresh water Plates Are Dirty With White Or Scale...

Page 10: ...Hex Nut at top of cell housing counter clockwise with a large wrench as shown in picture below The cell plates will turn with the Hex Nut Loosen the Hex Nut to a point that can be turned by hand Loos...

Page 11: ...ct or to explain the usage of the system to the buyer repairs necessitated by use other than normal home use damage resulting from misuse unintended use unforeseen use non pool or spa use abuse accide...

Page 12: ...prod uct Or register your product on line at www ControlOMatic com First Name Last Name Address City State Province Postal Code Phone E Mail Please copy this section and forward a copy to ControlOMat...

Reviews: