manualshive.com logo in svg
background image

Swimming pool heaters

Installation, maintenance & use instructions

TECHNICAL MANUAL

Содержание PARASOL

Страница 1: ...Swimming pool heaters Installation maintenance use instructions TECHNICAL MANUAL ...

Страница 2: ......

Страница 3: ... RATE TO AND FROM THE COLLECTORS 7 COLLECTOR PUMP 7 POINT OF CONNECTION BETWEEN SUPPLY TUBE AND THE COLLECTOR PUMP 7 POINT OF CONNECTION OF HEATED WATER FROM THE COLLECTOR 7 POINT OF CONNECTION OF THE TEMPERATURE SENSOR 8 NON RETURN VALVES 9 COLLECTOR S TECHNICAL INFORMATIONS 9 INSTALLATION DIAGRAM 10 PERFORMANCE GRAPH 11 CONTROL UNIT 11 CONNECTION DIAGRAM 12 CONNECTION GRAPH 13 TECHNICAL DRAWING ...

Страница 4: ...asol is not only a life choice but also an ecological and positive contribution to the environment Pools can be used for the extended period of March November or even longer depending on the hours of the solar irradiation Parasol offers you the ideal solution for an enjoyable summer the whole year round Warmth in practice Manufactured out of high quality recyclable plastic it is protected against ...

Страница 5: ...ildings trees etc y y The distance between the technical area swimming pool and the collector y y Collector temperature sensor y y Possible wind sensibility y y Use ground liner if placed directly on the ground Shading The collectors must be positioned so that they catch direct sunlight throughout the day If this proves to be problematic due to circumstances find an area with the most sunshine hou...

Страница 6: ...ube 20 mm PE 4 Sensor cable sensor P100 25mm 5 Temperature sensor holder stainless steal 1 Supply tube 2 Return tube South East Ground fabric liner If the collectors are placed on an untreated surface it is advisable to use fabric liner underneath the collector HOW TO FIX THE COLLECTOR S TEMPERATURE SENSOR HOW TO CONNECT THE COLLECTORS Connect the special PE T connection including the stainless st...

Страница 7: ...ate pools the supply tube of the collector pump has to be connected to the supply tube from the pool before the circulation pump or through a pre installation for heating systems Use a tube with sufficient diameter We advice to y y Use a ball cap to eventually isolate the solar collector system y y Place pools temperature sensor as close as possible to pool supply tube See also Connection Point te...

Страница 8: ...ctly to measure the pools water temperature as accurate as possible Possible positions A Supply tube of the filter pump preferred position When placed into the supply tube from the filter pump the sensor must be fixed before the diversion to the collector pump B Supply tube of collector pump 1b When placed into the supply tube of the collector pump the sensor 1b must be placed as close as possible...

Страница 9: ...alfunction within the system The pool does not heat up NOTE It is important to install the non return valves in the supply tubes that have the same tube diameter or more Just like the position of the pool sensor the usage of non return valves is crucial for this system s correct operation The filter pump and the collector pump are not always working at the same time Without the usage of the non re...

Страница 10: ...10 Nobel Xilinakis D Co preserves the right to change all specifications of the products and their accessories without prior notice INSTALLATION DIAGRAM ...

Страница 11: ...o preserves the right to change all specifications of the products and their accessories without prior notice PERFORMANCE GRAPH CONTROL UNIT Swimming pool Swimming pool with Parasol Collector Sensor and Holder Pool Sensor and Holder ...

Страница 12: ...12 Nobel Xilinakis D Co preserves the right to change all specifications of the products and their accessories without prior notice CONNECTION DIAGRAM ...

Страница 13: ...13 PARASOL Nobel Xilinakis D Co preserves the right to change all specifications of the products and their accessories without prior notice CONNECTION GRAPH TECHNICAL DRAWING ...

Страница 14: ... the desired pool temperature shown on the controller display in brackets Manual mode By pressing the auto man button we can change the controller to auto mode or manual mode Shown on display in manual mode manual time recorded in digits T off the manual mode we see the time during which the collector pump hasn t been working By pressing the arrow button up or down we can switch the collector pump...

Страница 15: ...a certain temperature difference is created between the pool and the solar collector the system will start operating Factory setting 2 5 degrees Don t change this value until instructed by factory DELTA T2 In this screen we can change the auto end time of the system When the positive temperature difference will fall below the factory setting the system will stop operating Factory setting 1 0 degre...

Страница 16: ...minutes per solar collector OFFSET S1 Solar collector sensor Calibration of the sensor possible from 5 0 till 5 0 OFFSET S2 Solar collector sensor Calibration of the sensor possible from 5 0 till 5 0 EXIT To leave the installer mode you need to press the auto man button You will now return to the auto mode 5 0 Installer Menu OFFSET S1 5 0 Installer Menu OFFSET S2 EXIT AUTO MAN AUTO MAN AUTO MAN AU...

Страница 17: ...17 PARASOL Nobel Xilinakis D Co preserves the right to change all specifications of the products and their accessories without prior notice PARASOL SUPPORT ...

Страница 18: ...18 Nobel Xilinakis D Co preserves the right to change all specifications of the products and their accessories without prior notice NOTES ...

Страница 19: ......

Страница 20: ... D Co SOLAR ELECTRIC WATER HEATING SYSTEMS INDUSTRY EXPORT DEPARTMENT 25 I Nika 136 73 Αcharnes Τel 30 210 2478677 Fax 30 210 2407185 HEADQUARTERS 23 Nerantzoulas 136 77 Αcharnes Τel 30 210 2404051 Fax 30 210 2443444 e mail info nobel gr ...

Отзывы: