- 18 -
LineFormat
LineFormat
SingleEnded/RS422
Controls the current electrical format of the selected
physical input or output Line.
User Output Selector
User Output Selector Selects which bit of the User Output register will be
set by UserOutputValue.
UserOutputValue
UserOutputValue
False/True
Sets the value of the bit selected by
UserOutputSelector.
UserOutputValueAll
UserOutputValueAll
Sets the value of all the bits of the User Output
register.
LineDetectionLevel
LineDetectionLevel
Threshold3V3
Threshold5V
LineDebouncingPeriod
LineDebouncingPeri
od
Min: -3.38
Max: 3.38
Default in nanosecond (ns)
4.3.5 EventControl
The following table describes each Event Control features.
Display Name
Feature&Values
Description
EventSelector
EventSelector
ExposureEnd
FrameTrigger
FrameStart
AcquisitionStart
AcquisitionTrigger
Selects which Event to signal to the host
application.
EventNotification
EventNotification
On/Off
Activate or deactivate the notification to
the host application of the occurrence of
the selected Event.
4.3.6 AnalogControl
The following table describes each Analog Control features.