- 19 -
Display Name
Feature&Values
Description
Gain Selector
Gain Selector
Selects which Gain is controlled by the various
Gain features.
Gain Raw
Gain Raw
Min: 0
Max: 6
Controls the selected gain as an absolute
physical value. This is an amplification factor
applied to the video signal.
BlackLevelSelector
BlackLevelSelector
Selects which tap is controlled by the Black
Level feature.
BlackLevel
BlackLevel
Min: 0
Max: 255
Controls the analog black level as an absolute
physical value. This represents a DC offset
applied to the video signal.
Gamma
Gamma
Min: 0
Max: 3.99998
Controls the gamma correction of pixel intensity.
This is typically used to compensate for
non-linearity of the display system (such as
CRT).
4.3.7 LUTControl
The following table describes each LUT Control features.
Display Name
Feature&Values
Description
LUTSelector
LUTSelector
Luminance
Selects which LUT to control.
LUTEnable
LUTEnable
False/True
Activates the selected LUT.
LUTIndex
LUTIndex
Min: 0
Max: 4095
Control the index (offset) of the coefficient to
access in the selected LUT.
LUTValue
LUTValue
Min: 0
Max: 4095
Returns the Value at entry LUTIndex of the
LUT selected by LUTSelector.
LUTValueAll
LUTValueAll
Accesses all the LUT coefficients in a single
access without using individual LUTIndex.
4.3.8 TransportLayerControl