![CONTRASTECH Mars Series User Manual Download Page 16](http://html1.mh-extra.com/html/contrastech/mars-series/mars-series_user-manual_2658163016.webp)
- 16 -
FallingEdge
The trigger is considered valid on
the falling edge
TriggerDelay
TriggerDelay
Specifies the delay in microseconds
(us) to apply after the trigger reception
before activating it.
TriggerMultiplier
TriggerMultiplier
Specifies a multiplication factor for the
incoming trigger pulses.
ExposureMode
ExposureMode
Timed
Trigger Width
Sets the operation mode for the
camera’s exposure.
The exposure duration time is set
using the
ExposureTime
feature.
Uses the width of the trigger
signal pulse to control the exposure
duration.
ExposureTime
ExposureTime
Sets the Exposure time when
ExposureMode is Timed and
ExposureAuto is Off. This controls the
duration where the photosensitive cells
are exposed to light.
ResultingLineRateAbs
ResultingLineRateAbs
Indicates the 'absolute' value of the
maximum allowed acquisition frame
rate. The 'absolute' value is a float value
that indicates the maximum allowed
acquisition frame rate in frames per
second given the current settings for the
area of interest, exposure time, and
bandwidth.
How to Set Frame Trigger: 1. Sets
TriggerSelector
as
FrameStart;
2. Sets
TriggerMode
as
ON;
3. Sets
TriggerSource
as corresponding trigger input(Line1/2/3). Please
refer to the
Table 3.3-1
for Input Signals Electrical Specifications.
4. Press
to view the images.
How to Set Line Trigger: 1. Sets
TriggerSelector
as
LineStart;
2. Sets
TriggerMode
as
ON;
3. Sets
TriggerSource
as corresponding trigger input(Line1/2/3). Please
refer to the
Table 3.3-1
for Input Signals Electrical Specifications.
4. Press
to view the images.
The following table is the Input Signals Electrical Specifications.
Signal
Description