ENGLISH
CONTRACOR
®
CAB-110P/CAB-135P Art. 15205/15206
27
media valve adjustment according to Section 4.3.2.
6.3.5
Worn out nozzle. Examine and replace if damaged or worn out.
6.3.6
Worn out blast hose. Inspect the hose for leaks and soft spots. Replace if
damaged or worn out.
6.3.7
The blast media is damp. Frequent bridges or blockage near the metering valve
can be caused by moisture. Refer to Section 5.1.4.
6.4. Plugged nozzle
6.4.1
A damaged or missing reclaimer screen will allow large particles to pass and
block the nozzle. Replace or re-install as necessary.
6.4.2
Media mixture too rich. Adjust media/air mixture per Section 4.3.2.
6.5. Air only (no media) comes out the nozzle
6.5.1
Ensure that media is in the machine.
6.5.2
Check that the media metering valve is not in the fully right position.
6.5.3
Check that the metering valve is not blocked by fully opening the metering valve
and closing the choke. Depress foot pedal to exhaust any obstacles. Should the problem not
be rectified by this procedure, release pressure in the machine and open metering valve and
check for foreign objects.
6.5.4
Ensure that the tubing leading to the diaphragm outlet valve is not blocked or leaking.
6.5.5
Media metering valve requires service. Refer to metering valve operating manual.
6.6. Neither media nor air comes out the nozzle
6.6.1
Release pressure in the machine and check for obstruction in the nozzle.
6.6.2
Check that that blast machine is pressurized by depressing the foot pedal. Is this
is not the case, refer to Section 6.8.
6.6.3
Ensure that metering valve and choke are opened.
6.7. Blasting does not Stop when the Pedal is Released
6.7.1
Air should be exhausted by the 3-way valve in the pedal when released. Should
this not be the case, inspect tubing for obstructions and inspect switches.
Summary of Contents for 15205
Page 2: ......
Page 79: ...CONTRACOR CAB 110P CAB 135P Art 15205 15206 79 1 80 2 81 3 85 4 88 5 97 6 103 7 108...
Page 80: ...CONTRACOR 3 9 80 1 1 2 3 4 5 6 7 8...
Page 82: ...CONTRACOR 3 9 82 2 CAB 110P 135P 1 100 2 3 19 18 33 20 21 22 23 24 25 26 27 29 30 32 31 28...
Page 85: ...CONTRACOR CAB 110P CAB 135P Art 15205 15206 85 3 3 1 1 2 3 25 50 SGV 4 3 2...
Page 86: ...CONTRACOR 3 9 86 3 3 6 5 5 0 8 0 3 1...
Page 89: ...CONTRACOR CAB 110P CAB 135P Art 15205 15206 89 4 1 3 4 1 4 4 1 2 I D 1...
Page 90: ...CONTRACOR 3 9 90 4 1 5 4 1 6 4 2 4 2 1 4 1 CAB 110P CAB 135P 20 kg 40 kg 4 2 2 3...
Page 91: ...CONTRACOR CAB 110P CAB 135P Art 15205 15206 91 4 2 3 4 2 4...
Page 92: ...CONTRACOR 3 9 92 4 5 3 I ON 70 150 4 2 5...
Page 93: ...CONTRACOR CAB 110P CAB 135P Art 15205 15206 93 OFF 0 4 3 4 3 1 5 6 4 3 2 30...
Page 94: ...CONTRACOR 3 9 94 4 3 3 3 4 3 4 4 1 5 50 75...
Page 95: ...CONTRACOR CAB 110P CAB 135P Art 15205 15206 95 4 3 5 4 4...
Page 96: ...CONTRACOR 3 9 96 4 3 6 4 5 0 5 6 0 6 0 4 3 7 5 2 60 4 5 5...
Page 97: ...CONTRACOR CAB 110P CAB 135P Art 15205 15206 97 5 5 1 5 1 1 SGV SGV 5 1 2 5 1 3 5 1 4 5 1 5...
Page 98: ...CONTRACOR 3 9 98 5 1 6 5 2 5 2 1 5 2 2 2 5 2 3 5 2 5...
Page 99: ...CONTRACOR CAB 110P CAB 135P Art 15205 15206 99 6 5 2 4 7 7...
Page 100: ...CONTRACOR 3 9 100 9 8 5 2 5 5 2 4 3 9...
Page 101: ...CONTRACOR CAB 110P CAB 135P Art 15205 15206 101 5 2 6 10...
Page 102: ...CONTRACOR 3 9 102 5 2 7 5 2 7 0 4 5 5 2 8 4 5 1 2 7 1 2 1 6 3 8 3 2 8 1 7 6 3 5 4 11...
Page 119: ......