61
TECHNICAL
& CARE
System Specifications
Test Sample: Capillary whole blood
Test Result: Referenced to plasma/serum glucose
Sample Volume: 0.6 μL
Measuring Range: 1.1 mmol/L to 33.3 mmol/L
Countdown Time: 5 seconds
Memory: Stores most recent 1000 test results
Battery Type: Non-serviceable, 250mAh rechargeable lithium polymer battery, 3.4V –
4.2V (5V input voltage)
Meter/Battery Life: 5 years
Charging Current: 300 mA
Strip Storage Temperature Range:
0ºC
30ºC
Normal Control Storage Temperature Range:
9ºC
30ºC
Control Solution Operating Temperature Range:
15
35
Meter Operating Temperature Range:
5ºC
45ºC
Meter Operating Humidity Range: 10%–93% RH
Dimensions: 97 mm wide x 31 mm high x 18 mm thick
Weight: 43 grams
Sound Output: 45 to 80 dBA at a distance of 10 cm
Radio Transmitter Frequency: 2.4 GHz
Radio Transmitter Frequency: Maximum Radio Transmitter Power: 0 dBi EIRP
Electromagnetic Compatibility (EMC): The C
ONTOUR
®
N
EXT
LINK 2.4 meter complies
with the electromagnetic requirement specified in ISO 15197: 2013. Electromagnetic
emissions are low and unlikely to interfere with other nearby electronic equipment,
nor are emissions from nearby electronic equipment likely to interfere with the
C
ONTOUR
N
EXT
LINK 2.4 meter. The C
ONTOUR
N
EXT
LINK 2.4 meter meets the
requirements of IEC 61000-4-2 for immunity to electrostatic discharge. Avoid use
of electronic devices in very dry environments, especially if synthetic materials are
present. The C
ONTOUR
N
EXT
LINK 2.4 meter meets the requirements of IEC 61326-1
for radio frequency interference. To avoid radio frequency interference do not use the
C
ONTOUR
N
EXT
LINK 2.4 meter near electrical or electronic equipment that are sources
of electromagnetic radiation, as these may interfere with the proper operation of the
meter.
System
Specifications
81552940_CntrNextLINK2_4_UG_EN_FpBp_v5.indd 61
8/19/16 7:25 AM
TECHNICAL
& CARE
60
Symbols Used
The following symbols are used throughout the product labeling for the C
ONTOUR
®
N
EXT
LINK 2.4
blood glucose monitoring system (meter packaging and labeling, and reagent and control solution
packaging and labeling).
®
Symbols Used
Symbol
Symbol
What It Means
What It Means
Use by date (last day of month)
Control Range Normal
Batch code
Control Range Low
5ºC
45ºC
Temperature limitations
Control Range High
Consult instructions for use
Do not reuse
In Vitro Diagnostic Medical Device
Sterilized using irradiation
Catalogue number
Shake 15 times
Recycle Packaging
Caution
Number of test strips included
Batteries must be disposed of in accordance with laws in your country. Contact your
competent local authority for information on the relevant laws regarding disposal and
recycling in your area.
The meter should be treated as contaminated and disposed of according to local
safety rules. It should not be disposed of with waste electronic equipment.
The USB cable is waste electrical and electronic equipment. Do not dispose in
household waste. Remember to respect local regulations.
Symbol
What It Means
Contact your health care professional or local waste disposal authority for medical waste
disposal guidelines.
81552940_CntrNextLINK2_4_UG_EN_FpBp_v6.indd 60
9/16/16 7:40 AM
61
TECHNICAL
& CARE
System Specifications
Test Sample: Capillary whole blood
Test Result: Referenced to plasma/serum glucose
Sample Volume: 0.6 μL
Measuring Range: 1.1 mmol/L to 33.3 mmol/L
Countdown Time: 5 seconds
Memory: Stores most recent 1000 test results
Battery Type: Non-serviceable, 250mAh rechargeable lithium polymer battery, 3.4V –
4.2V (5V input voltage)
Meter/Battery Life: 5 years
Charging Current: 300 mA
Strip Storage Temperature Range:
0ºC
30ºC
Normal Control Storage Temperature Range:
9ºC
30ºC
Control Solution Operating Temperature Range:
15
35
Meter Operating Temperature Range:
5ºC
45ºC
Meter Operating Humidity Range: 10%–93% RH
Dimensions: 97 mm wide x 31 mm high x 18 mm thick
Weight: 43 grams
Sound Output: 45 to 80 dBA at a distance of 10 cm
Radio Transmitter Frequency: 2.4 GHz
Radio Transmitter Frequency: Maximum Radio Transmitter Power: 0 dBi EIRP
Electromagnetic Compatibility (EMC): The C
ONTOUR
®
N
EXT
LINK 2.4 meter complies
with the electromagnetic requirement specified in ISO 15197: 2013. Electromagnetic
emissions are low and unlikely to interfere with other nearby electronic equipment,
nor are emissions from nearby electronic equipment likely to interfere with the
C
ONTOUR
N
EXT
LINK 2.4 meter. The C
ONTOUR
N
EXT
LINK 2.4 meter meets the
requirements of IEC 61000-4-2 for immunity to electrostatic discharge. Avoid use
of electronic devices in very dry environments, especially if synthetic materials are
present. The C
ONTOUR
N
EXT
LINK 2.4 meter meets the requirements of IEC 61326-1
for radio frequency interference. To avoid radio frequency interference do not use the
C
ONTOUR
N
EXT
LINK 2.4 meter near electrical or electronic equipment that are sources
of electromagnetic radiation, as these may interfere with the proper operation of the
meter.
System
Specifications
81552940_CntrNextLINK2_4_UG_EN_FpBp_v5.indd 61
8/19/16 7:25 AM
TECHNICAL
& CARE
60
Symbols Used
The following symbols are used throughout the product labeling for the C
ONTOUR
®
N
EXT
LINK 2.4
blood glucose monitoring system (meter packaging and labeling, and reagent and control solution
packaging and labeling).
®
Symbols Used
Symbol
Symbol
What It Means
What It Means
Use by date (last day of month)
Control Range Normal
Batch code
Control Range Low
5ºC
45ºC
Temperature limitations
Control Range High
Consult instructions for use
Do not reuse
In Vitro Diagnostic Medical Device
Sterilized using irradiation
Catalogue number
Shake 15 times
Recycle Packaging
Caution
Number of test strips included
Batteries must be disposed of in accordance with laws in your country. Contact your
competent local authority for information on the relevant laws regarding disposal and
recycling in your area.
The meter should be treated as contaminated and disposed of according to local
safety rules. It should not be disposed of with waste electronic equipment.
The USB cable is waste electrical and electronic equipment. Do not dispose in
household waste. Remember to respect local regulations.
Symbol
What It Means
Contact your health care professional or local waste disposal authority for medical waste
disposal guidelines.
81552940_CntrNextLINK2_4_UG_EN_FpBp_v6.indd 60
9/16/16 7:40 AM
81552940_CntrNextLINK2_4_UG_EN_FpBp_v6_placed.pdf:64