C:I_LIM, C:I_ACT
Integrator control function
Command
Parameter
Unit
Group
C:I_LIM
X
C:I_ACT
X
x= 0… 10000
x= 0… 10000
0.01 %
0.01 %
STD
The integrator function is controlled by this command.
C:I_LIM
Limitation of the integrator range (faster control function by reduced pressure
overshoots). By a high nonlinearity of the valve the LIM value must be
sufficient to compensate it.
C:I_ACT
Controls the integrator function. To reduce pressure overshoots, an activation
point for the integrator can be programmed via the (I_ACT) value. The
integrator is activated if the actual pressure is higher than the programmed
threshold: