8
W415-0380 / E / 08.31.12
2.4 RATING PLATE INFORMATION
CERTIFIED UNDER: ANSI Z21.11.2a-2008 VOLUME II, UNVENTED ROOM HEATER
W385-0248 / G
SERIAL NUMBER:
G/CVF42
WOLF STEEL LTD.
24 NAPOLEON ROAD, BARRIE, ON, L4M 0G8 CANADA
THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET,
PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME, WHERE
NOT PROHIBITED BY LOCAL CODES. THIS APPLIANCE IS ONLY FOR USE
WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.
THIS IS A GAS-FIRED UNVENTED ROOM HEATER THAT REQUIRES
ADEQUATE COMBUSTION AND VENTILATION AIR. THIS UNIT IS NOT
APPROVED FOR BEDROOM, BATHROOM AND BED-SITTING ROOM
INSTALLATION.
GVF42-N / CVF42-N
MODEL
GVF42-P / CVF42-P
**0-2000FT (0-610m)
ALTITUDE
0-2000FT (0-610m)**
30,000 BTU/h
INPUT
30,000 BTU/h
22,000 BTU/h
REDUCED INPUT
22,000 BTU/h
MANIFOLD PRESSURE:
3.5" WATER COLUMN
MANIFOLD PRESSURE:
10" WATER COLUMN
MINIMUM SUPPLY PRESSURE:
4.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE:
11" WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
7.0" WATER COLUMN
MAXIMUM SUPPLY PRESSURE:
13" WATER COLUMN
SIT CONTROL:
#820637
SIT CONTROL:
#820636
OPERATING PILOT OXYPROTECTOR:
#8214
OPERATING PILOT OXYPROTECTOR:
#8404
**
ABOVE 2,000FT, CONSULT LOCAL AUTHORITY HAVING JURISDICTION
NOT FOR USE WITH SOLID FUEL.
WARNING: FIREPLACE SCREENS MUST BE CLOSED WHILE IN OPERATION.
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. DONOT USE BLOWER INSERT, HEAT EXCHANGER INSERT OR OTHER
ACCESSORIES NOT APPROVED FOR USE WITH THIS HEATER. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTAINANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE. REFER TO THE OWNER'S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS:
TOP / SIDES / BACK / FLOOR 0”
RECESSED DEPTH
22“
MANTEL
2”*
MAXIMUM HORIZONTAL EXTENSION: 2". SEE INSTRUCTION MANUAL FOR GREATER
EXTENSIONS.
ELECTRICAL RATING: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT: GZ550-KT
9700539 (WSL)
4001657 (NGZ)
4001658
(NAC)
4001659
(WUSA)
SAMPLE
M 0G8
M 0G
UA
A
TE
TE
A
A
A
R
R
OVE
OVE
D
D
FO
S
S
T
T
ALL
ALL
T
T
T
A
A
L
L
L
TIO
TIO
A
A
A
N
N
.
.
DEL
DEL
GV
GV
LTITUDE
TITUDE
INPUT
INPUT
REDUCED INPUT
EDUCED INPUT
LLL
COLUMN
OLUMN
MANIFOLD PR
MAN
R COLUMN
R COLUM
MINIMUM S
MINI
TER COLUMN
ER COLUMN
MAXIMUM
MAXIM
NTROL:
L:
#820637
#820637
SIT CO
SIT CO
ROTECTOR:
ROTECTOR:
#8214
#8214
OPE
PE
,000FT, CONSULT LOCAL AU
000FT, CONSULT LOCAL AU
NOT FOR USE W
T FOR USE W
E CLOSE
CLOS
D WHILE IN
WHILE IN
BY THE MANUFACTURER WIT
Y THE MANUFACTURER WIT
ER. IMPROPER INSTALLATION
MPROPER INSTALLATIO
ORMATION MANUAL PROVIDE
ON MANUAL PROVID
E MATERIALS:
E MATERIALS:
22“
4001657 (NGZ)
GZ)
4001659 (WUSA)
4001659 (WUSA)
L
L
L
L
This illustration is for reference only. Refer to the rating plate on the appliance for accurate information.
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the appliance.
For rating plate location, see “INSTALLATION OVERVIEW” section.
NOTE: The rating plate must remain with the appliance at all times. It must not be removed.