W415-1150 / 02.28.13
48
EN
A.
Remove the glass door. See "DOOR REMOVAL AND INSTALLATION" section. Remove the burners,
see "BURNER REMOVAL" section.
B.
Remove the 12 screws holding the valve train in place.
NOTE:
A new gasket may be required when reinstalling the valve train assembly. Contact your
local authorized dealer/distributor.
C.
Carefully lift the valve train assembly out far enough to access the manual shut off valve and turn to
the off position. Disconnect the
fl
ex connector from the valve. You may now lift the valve train out of the
appliance.
77.3
Vertical installations may display a very active
fl
ame. If this appearance is not desirable, the vent exit must
be restricted using a restrictor vent kit. Refer to “ACCESORIES” in the “REPLACEMENTS” section for the
appropriate kit. This will reduce the velocity of the exhaust gases, slowing down the
fl
ame pattern and creating
a more traditional gentle
fl
ame appearance. Speci
fi
c instructions are included with the kit.
10.5 VALVE TRAIN REPLACEMENT
10.6 RESTRICTING VERTICAL VENTS