évacuation

FR

2.4  charte d'application des évacuations

2.5 légende

2.6valeur du coude en longueur d'évent

10.1

Évacuation sur le dessus

Terminaison horizontale

La course verticale est 

plus grande ou égale à 

la course horizontale

La course verticale 

est plus grande ou 

égale à la course 

horizontale

La course verticale 

est plus petite que la 

course horizontale

La course verticale 

est plus petite que la 

course horizontale

La course horizontale 

+ la course verticale 

jusqu’à un maximum 

de 24,75’ (7,5m)

La course horizontale 

+ la course verticale 

jusqu’à un maximum 

19’ (5,8m)

4,2 fois la course 

verticale plus grande 

ou égale à la course 

horizontale

3 fois la course 

verticale plus grande 

ou égale à la course 

horizontale

La course horizontale 

+ la course verticale 

jusqu’à un maximum 

de 40’ (12,2m)

La course horizontale 

+ la course verticale 

jusqu’à un maximum 

de 40’ (12,2m)

Terminaison verticale

11.1

Les symboles suivants sont utilisés dans le calcul et les exemples d’évacuation :

> - plus grand que

> - plus grand ou égal à

< - plus petit que

< - plus petit ou égal à

H

T

 - total de la longueur des courses horizontales (H

R

) plus la valeur des déviations (H

O

) en pieds

H

R

 - longueur des courses horizontales combinées en pieds

H

O

 - facteur de la valeur d’une déviation : 0,03 (du total des degrés de déviation - 90°*) en pieds

H

O

 - facteur de la valeur d’une déviation : 0,03 (total des degrés de déviation - 135°*) en pieds

V

T

 - longueur des courses verticales combinées en pieds

12.1

 

Pieds  

Pouces  

Millimètres

1° 

  0,03   

     0,5   

12,7

15° 

  0,45    

     6,0   

152,4

30° 

  0,9    

    11,0   

279,4

45° 

  1,35   

    16,0   

406,4

90°*     2,7    

    32,0   

812,8

* La première déviation de 90° a une valeur zéro et est illustrée dans la formule comme - 90°

.

* La première déviation de 45° et de 90° a une valeur zéro et est illustrée dans la formule comme -45° et -90º

respectivement ou -135° lorsque combinées 

(Pour la 45° sortie seulement).

Summary of Contents for CDVS500-1

Page 1: ...call the re department Installation and service must be performed by a quali ed installer service agency or the supplier This appliance may be installed in an aftermarket permanently located manufact...

Page 2: ...m touching hot surfaces Even after the appliance is off it will remain hot for an extended period of time Check with your local hearth specialty dealer for safety screens and hearth guards to protect...

Page 3: ...and repair should be done by a qualified service person It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean For outdoor products only this...

Page 4: ...ural vent 24 3 2 4 combustion air 24 3 2 5 natural vent adaptations 25 3 2 6 adding vent sections 26 note The information throughout this manual is believed to be correct at the time of printing Wolf...

Page 5: ...pansion contraction noises during heating up and cooling down cycles are normal and to be expected This appliance is only for use with the type of gas indicated on the rating plate This appliance is n...

Page 6: ...bathroom unless the unit is a direct vent sealed combustion product The installation must conform with local codes or in absence of local codes the National Gas and Propane Installation Code CSA B149...

Page 7: ...in contact with the flames other than that supplied by the manufacturer with the appliance AVERTISSEMENT N ajoutez pas cet appareil aucun mat riau devant entretien contact avec les flammes autre que...

Page 8: ...11 22 EN 8 general information GAS LINE LOCATED IN PEDESTAL REAR 28 1 4 718mm 14 1 8 359mm 21 5 8 549mm 8 203mm 7 178mm AIR INTAKE 4 102mm FLUE 13 3 4 349mm 21 533mm 30 3 4 781mm SAFETY BARRIER 2 51mm...

Page 9: ...tical and horizontal runs Spacers are attached to the inner pipe at predetermined intervals to maintain an even air gap to the outer pipe This gap is required for safe operation A spacer is required a...

Page 10: ...proper operation of the appliance follow the venting instructions exactly A terminal shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellin...

Page 11: ...m air slot is located a minimum 12 305mm above grade The maximum allowable vent length including both rise and run is 10 3m for a fireplace and 8 2m for a stove An insulation sleeve is illustrated in...

Page 12: ...m an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without openings Q 3 0 9m 3 0 9m See chart for wider wall dimensions R 6 1 8m 6 1 8m See chart for deep...

Page 13: ...maximum of 40 feet 12 2m Horizontal run vertical rise to maximum of 40 feet 12 2m Vertical Termination 11 1 For the following symbols used in the venting calculations and examples are greater than eq...

Page 14: ...4m H1 2 5 FT 0 8m H2 2 FT 0 6m HR H1 H2 2 5 FT 0 8m 2 FT 0 6m 4 5 FT 1 4m HO 03 three 90 elbows 90 03 270 90 5 4 FT 1 7m HT HR HO 4 5 FT 1 4m 5 4 FT 1 7m 9 9 FT 3m HT VT 9 9 FT 3m 11 FT 3 4m 20 9 FT...

Page 15: ...m 16 7FT 5 1m 24 75 FT 7 5m Since both formulas are met this vent configuration is acceptable HORIZONTAL VENT RUN PLUS OFFSET IN FEET METERS HT The shaded area within the lines represents acceptable v...

Page 16: ...5 FT 1 5m V2 6 FT 1 8m V3 10 FT 3 1m VT V1 V2 V3 5FT 1 5m 6FT 1 8m 10FT 3 1m 21FT 6 4m H1 8 FT 2 4m H2 2 5 FT 0 8m HR H1 H2 8FT 2 4m 2 5FT 0 8m 10 5 FT 3 2m HO 03 four 90 elbows 90 03 360 90 8 1 FT 2...

Page 17: ...1 H2 6FT 1 8m 2FT 0 6m 8 FT 2 4m HO 03 four 90 elbows 90 03 360 90 8 1 FT 2 5m HT HR HO 8FT 2 4m 8 1FT 2 5m 16 1FT 4 9m HT VT 16 1FT 4 9m 4 5FT 1 4m 20 6 FT 6 3m Formula 1 HT 3VT 3VT 3FT 0 9m x 4 5FT...

Page 18: ...r intake flex liner and the exhaust collar must be connected to the exhaust flexible liner Both Simpson Duravent and Selkirk co linear to co axial adaptors have been approved on this appliance Follow...

Page 19: ...ox prior to connecting the gas and electrical supply If your appliance is supplied with a remote ensure the remote receiver is in the OFF position prior to connecting the gas and electrical supply to...

Page 20: ...Installation kits for various roof pitches are available from your authorized dealer distributor See the accessories section to order specific kits required A Determine the air terminal location cut...

Page 21: ...with a minimum of 3 screws Seal using red RTV silicone W573 0002 not supplied C Insert the vent pipes through the firestop maintaining the required clearance to combustibles Holding the air terminal...

Page 22: ...er the air terminal connector leaving a min 3 4 19mm of the air terminal connector showing above the top of the flashing Slide the flashing underneath the sides and upper edge of the shingles Ensure t...

Page 23: ...on is completed An optional decorative black band may be available with this appliance In the event that the venting must be disassembled care must be taken to reseal the venting 1 1 2 38 1mm Overlap...

Page 24: ...tch opening To pass the wires through the hole more easily temporarily tape the two terminals together With the spill switch opening aligned to the back of the appliance take hold of the adaptor base...

Page 25: ...hat the thermodisc firmly touches the underside of the burner tray and tighten This enables the blower to function properly D Secure the terminal block into place as shown with the screw supplied E Ge...

Page 26: ...e chimney extends more than 5ft 1 5m above the roof it must be secured using a roof brace or guide wires A raincap must be installed to avoid internal damage and corrosion 3 FT 1m MIN 3 FT 1m MIN 10 F...

Page 27: ...est pressures above 1 2 PSIG Valve settings have been factory set do not change Installation and servicing to be done by a qualified installer Move the appliance into position and secure If equipped w...

Page 28: ...not touch glass until cooled If equipped with door latches that are part of a safety system they must be properly engaged Do not operate the appliance with latches disengaged Before door is removed t...

Page 29: ...atch handles towards you and release each catch The door may now be safely opened To close the door repeat in reverse order There may be instances that require adjustment of the door latches to ensure...

Page 30: ...ance may not function properly and delayed ignition may occur The logs are fragile and should be handled with care 48 1 LOG SUPPORTS 1 2 3 4 1 Place the 2 piece charcoal ember strip along the edge of...

Page 31: ...es as indicated 5 4 trivet installation Insert the trivet into the space on the appliance top Line up the holes in the brackets and secure using the screw provided BRACKET 5 5 control access cover rem...

Page 32: ...use any other type of battery pack note BATTERY HOLDER GAS VALVE PILOT ASSEMBLY IGNITION MODULE PILOT GAS LINE I S AC ADAPTOR BATTERY RELAY WIRE HARNESS MAIN BURNER SWITCH JUNCTION BOX NOTE PLUGTHE 3...

Page 33: ...to the transmitter Set thermostat to desired setting if equipped I Turn on the remote wall switch to the appliance J If the appliance will not operate follow instructions TO TURN OFF GAS and call your...

Page 34: ...build up of carbon monoxide or an explosion of unburnt gases during start up If the flue is blocked or has no draw the spill switch will automatically shut off the supply of gas within about 5 10 minu...

Page 35: ...4mb Outlet 3 5 8 7mb 10 24 9mb FLAME MUST ENVELOP UPPER 3 8 9 5mm TO 1 2 12 7mm OF FLAME SENSOR PILOT BURNER ELECTRODE FLAME SENSOR 3 8 1 2 9 5mm 12 7mm A B PILOT OUTLET A B SORTIE DE PILOTE TOP VIEW...

Page 36: ...abnormal call a service person ADD IMAGE HERE 36 1 12 7mm 9 5mm of thermocouple Flame must envelop upper 3 8 to 1 2 12 7mm 9 5mm of Flame sensor SIT ELECTRONIC IGNITION 3 8 1 2 9 5mm 12 7mm 3 8 1 2 9...

Page 37: ...ding living area inside the firebox and on exterior surfaces sur rounding vent termination 8 Check to see that the main burner ignites completely on all ports when turned on A 5 to 10 second total lig...

Page 38: ...otch Brite to remove any oxides Clean the pilot assembly using a vacuum with a soft brush attachment It is important that the pilot assembly is not painted note A Turn off the electrical power and the...

Page 39: ...until the fire is out Do not operate the appliance until the glass has been replaced Contact you local authorized dealer distributor for replacement parts DO NOT SUBSTITUTE MATERIALS 5 1A Vinegar bas...

Page 40: ...warranty replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts always give the following information Model Serial Number of applian...

Page 41: ...290 0032 Door magnet catch X2 W430 0002 Left side door assembly W010 3526 Log set GL 642 W010 3524 Control door assembly 11 10 4 5 6 7 8 9 W390 0001 Door latch X2 W690 0002 Yes 23 W750 0491 Power cord...

Page 42: ...W175 0281 Manifold flex pipe W350 0342 Battery back up Yes Yes Part not illustrated 14 16 14 15 14 13 8 7 W335 0039 Pilot hood W290 0029 Pilot gasket Yes Yes 5 6 6 Yes W725 0105 Valve P W725 0104 Valv...

Page 43: ...iption Safety barrier assembly Items may not appear exactly as illustrated 1 Stocked 3 4 5 23 23 23 3 23 1 5 4 23 2 W030 0021SC 2 Accent bar Satin Chrome W660 0081 Wall mounted thermostat F45 F60 Hand...

Page 44: ...nging on the glass logs rocks media or combus tion chamber Ensure the media is positioned correctly in the appliance Open air shutter to increase the primary air Check the input rate check the manifol...

Page 45: ...m hold reset button on receiver and wait for 2 beeps Release after second beep Press small flame button on remote within 20 seconds you will hear an additional beep this signals a successful reset Rep...

Page 46: ...n the receiver is in the remote position middle Transmitter isn t operational Check battery power and battery orientation Wire connector pins are bent Straighten pins Valve wiring is damaged Replace v...

Page 47: ...h as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting configurations insufficient makeup air or negative air pressures which may or may not be caused b...

Page 48: ...Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Crittenden Kentucky USA 41030 7200 Route Transcanadienne Montr al Qu bec Canada H4T 1A3 P 1 866 820 8686...

Page 49: ...stall dans une maison pr fabriqu e mobile d j install e demeure si les r glements locaux le permettent Cet appareil doit tre utilis uniquement avec le type de gaz indiqu sur la plaque d homologation C...

Page 50: ...ts et loin des meubles et des rideaux Les meubles ou autres objets doivent tre gard s une distance d au moins 4 pieds 1 22m du devant de l appareil Assurez vous de disposer de mesures de s curit ad qu...

Page 51: ...riaux d emballage hors de la port e des enfants et mettez ces mat riaux au rebut de fa on s curitaire Comme tous les emballages de plastique ces mat riaux ne sont pas des jouets et doivent demeurer h...

Page 52: ...nstallation verticale 68 3 1 3 installation de la terminaison horizontale 69 3 1 4 installation de la terminaison verticale 70 3 1 5 raccordement des vents l appareil 71 3 2 installation de l vent de...

Page 53: ...ndre Cet appareil ne doit fonctionner qu avec le gaz sp cifi sur la plaque d homologation Cet appareil ne peut tre converti un autre type de gaz moins d utiliser un ensemble de conversion certifi Appa...

Page 54: ...que 36 pouces 914 4mm Un d tecteur de monoxyde de carbone est requis dans toutes les pi ces contenant des appareils aliment s au gaz L appareil n est pas approuv pour installation dans une chambre cou...

Page 55: ...e X de l ouverture de l appareil WARNING Do not add any material to the appliance which will come in contact with the flames other than that supplied by the manufacturer with the appliance AVERTISSEME...

Page 56: ...information g n rales 1 4 dimensions CONDUITE DE GAZ SITU E L ARRI RE DU PI DESTAL PRISE D A IR BUSE 28 1 4 718mm 14 1 8 359mm 21 5 8 549mm 8 203mm 7 178mm 4 102mm 13 3 4 349mm 21 533mm 30 3 4 781mm...

Page 57: ...en tout temps V rifiez la prise d air de la terminaison au moins une fois l an pour vous assurer qu elle n est pas obstru e ni endommag e Ne combinez pas de composants rigides ou flexibles ni de compo...

Page 58: ...l vation minimum de 1 4 par pied ou 21mm par m tre lors d utilisation d vacuation flexible Afin d assurer un fonctionnement s curitaire et ad quat de l appareil vous devez observez les instructions d...

Page 59: ...m au dessus du niveau du sol La longueur maximale permise de l vent comprenant l hauteur et la longueur est 10 pieds 3m pour une foyer et 8 pieds 2m pour une po le Un manchon isolant est illustr dans...

Page 60: ...u pour les dimensions d un mur plus large R 6 1 8m 6 1 8m Voir la tableau pour les dimensions d un mur plus profond La terminaison ne doit pas tre install e sur quelconque mur ayant une ouverture entr...

Page 61: ...e horizontale la course verticale jusqu un maximum de 40 12 2m Terminaison verticale 11 1 Les symboles suivants sont utilis s dans le calcul et les exemples d vacuation plus grand que plus grand ou ga...

Page 62: ...I 1 4m 5 4 PI 1 7m 9 9 PI 3m HT VT 9 9 PI 3m 11 PI 3 4m 20 9 PI 6 4m Formule 1 HT VT 9 9 PI 3m 11 PI 3 4m Formule 2 HT VT 40 PI 12 2m 20 9 PI 6 4m 40 PI 12 2m Puisque les deux formules sont respect es...

Page 63: ...7 7m 10 7PI 3 3m 25 2 PI 7 7m Formule 2 HT VT 24 75 PI 7 5m 16 7PI 5 1m 24 75 PI 7 5m Puisque les deux formules sont respect es cette configuration d vacuation est acceptable Exemple V1 4 PI 1 2m V2...

Page 64: ...12 2m Exemple V1 5 PI 1 5m V2 6 PI 1 8m V3 10 PI 3 1m VT V1 V2 V3 5PI 1 5m 6PI 1 8m 10PI 3 1m 21 PI 6 4m H1 8 PI 2 4m H2 2 5 PI 0 8m HR H1 H2 8 PI 2 4m 2 5 PI 0 8m 10 5 PI 3 2m HO 0 03 quatre coudes 9...

Page 65: ...m 2PI 0 6m 8 PI 2 4m HO 0 03 quatre coudes 90 90 0 03 360 90 8 1 PI 2 5m HT HR HO 8 PI 2 4m 8 1 PI 2 5m 16 1 PI 4 9m HT VT 16 1PI 4 9m 4 5PI 1 4m 20 6 PI 6 3m Formule 1 HT 3VT 3VT 3PI 0 9m x 4 5PI 1 4...

Page 66: ...tre raccord au conduit flexible de prise d air et le collet d vacuation de la terminaison au conduit flexible d vacuation Les adaptateurs colin aire coaxial Simpson Duravent et Selkirk sont approuv s...

Page 67: ...ents pour l alimentation en gaz et lectronique Afin d assurer un fonctionnement s curitaire et ad quat de l appareil vous devez observer les instructions d vacuation la lettre Tous les joints des cond...

Page 68: ...e Cette configuration s applique lorsque l vacuation se fait travers un toit Des ensembles d installation pour les diff rentes pentes de toit sont disponibles chez votre d taillant autoris Voir la sec...

Page 69: ...in de maintenir cet espace vide N enlevez pas ces espaceurs AVERTISSEMENT A tirez la gaine flexible int rieure la longueur requise en tenant compte de la longueur additionnelle n cessaire pour la surf...

Page 70: ...necteur de terminaison en laissant un minimum de 3 4 19 1mm de connecteur de terminaison visible au dessus du haut du solin Glissez le solin sous les c t s et le bord sup rieur des bardeaux Assurez vo...

Page 71: ...l faudra prendre soin de sceller les vents nouveau 1 1 2 38 1mm chevauchement REAR VENT 1 1 4 31 8mm chevauchement TOP VENT FLEX TOP VENT RIGID FLEX Scellant haute temp rature 8 X 1 2 vis autoperceuse...

Page 72: ...du collet de 7 178mm au dessus du po le environ 8 203mm l ext rieur Passez les fils travers le trou inf rieur de l adaptateur et par l ouverture de l interrupteur d coulement Afin de passer les fils...

Page 73: ...ite que le thermodisque est bien appuy sur le dessous du plateau du br leur et resserrez Ceci permet la soufflerie de fonctionner convenablement D Fixez le bloc de branchement avec les vis fournies co...

Page 74: ...5m elle devra tre fix e au toit avec un support de toit ou des brides de s curit Un chapeau de chemin e devra tre install afin d viter des dommages internes et la corrosion 3 PI 1m MIN 3 PI 1m MIN 10...

Page 75: ...sions d essai exc dent 1 2 LB PO2 3 5 KPA Les r glages de la soupape ont t faits en usine ne les modifiez pas L installation et l entretien doivent tre effectu es par un installateur qualifi Mettez l...

Page 76: ...qu elle ait refroidi Les loquets de porte font partie d un dispositif de s curit et doivent tre ad quatement verrouill s Ne faites pas fonctionner l appareil lorsque les loquets sont d verrouill s Ava...

Page 77: ...les poign es vers vous et d clenchez chaque loquet La porte peut maintenant tre ouverte sans danger Pour fermer la porte r p tez le proc d l inverse Dans certains cas la tension des loquets devra tre...

Page 78: ...fonctionner ad quatement et un retard d allumage risque de se produire Les b ches sont fragiles et devraient tre manipul es avec soin 48 1 LOG SUPPORTS 1 2 3 4 1 Placez les deux b bandes de charbon d...

Page 79: ...la grille Ins rez la grille dans l espace sur le dessus de l appareil Alignez les trous des supports et fixez l aide des vis fournies SUPPORT 4 5 l enl vement installation du couvercle d acc s du con...

Page 80: ...az l alimentation lectrique 110 V AVERTISSEMENT SAUVEGARDEDE PILES I S ADAPTEUR HARNAIS DE FILS MAIN BURNER SWITCH 1 4 3 16 3 8 1 2 9 5mm 12 7mm LA FLAMME DOIT ENVELOPPER LA PARTIE SUP RIEURE DE LA SO...

Page 81: ...eur murale de l appareil la position ON J Si l appareil ne fonctionne pas suivre les instructions de couper l alimentation de gaz et puis appelez votre technicien de service ou fournisseur de gaz A R...

Page 82: ...conduit est bloqu ou en absence de tirage l interrupteur d coulement coupera automatiquement l arriv e de gaz dans les 5 10 minutes LA MODIFICATION DE L INTERRUPTEUR PEUT PROVOQUER UN EMPOISONNEMENT P...

Page 83: ...iez pour des fuites en appliquant une solution d eau savonneuse Pression d alimentation maximale ne devait pas d passer 13 Pression Gaz Natural pouces Gaz Naturel millibars Propane pouces Propane mill...

Page 84: ...actez un technicien de service ADD IMAGE HERE 36 1 3 8 1 2 9 5mm 12 7mm Flame must envelop upper 3 8 to 1 2 12 7mm 9 5mm of thermocouple thermopile 3 8 1 2 9 5mm 12 7mm La flamme doit envelopper la th...

Page 85: ...assez puissante pour envelopper la sonde de flamme et ou le thermocouple thermopile et qu elle atteigne le br leur 5 Si votre appareil est fourni avec une cran de protection le nettoyage peut tre n c...

Page 86: ...orte vitr e ou par les clapets sur le dessus du caisson Assurez vous qu ils ouvrent sans restriction et qu ils ferment de fa on tanche Si la vitre de la porte est fissur remplacer Seulement utiliser l...

Page 87: ...rqu e en permanance Ne touchez pas la surface int rieure ou ext rieur de la vitre avec des lames de rasoir de la laine d acier ou d autres objets m talliques puisque la mince couche de m tal retir e d...

Page 88: ...ement de pi ce sous garantie une photocopie de la facture originale sera requise afin de pouvoir honorer la demande Lorsque vous commandez des pi ces donnez toujours l information suivante Mod le et n...

Page 89: ...e porte X2 W430 0002 Assemblage de la porte du c t gauche W010 3526 Ensemble de b ches GL 642 W010 3524 Porte du bo tier de commande 11 10 4 5 6 7 8 9 23 22 20 19 21 16 15 14 12 13 17 18 W390 0001 Loq...

Page 90: ...14 14 14 14 14 1 2 3 5 6 7 2 1 3 4 5 6 6 11 12 13 13 14 10 W455 0068 Injecteur du veilleuse 35 P W720 0062 Oui W725 0105 Soupape P W725 0104 Soupape GN 9 14 4 W380 0001 Oui Oui Oui Oui W240 0016 Oui 3...

Page 91: ...llustr 23 23 23 3 5 4 R f No de pi ce Description 2 GS350SSB 1 En stock W135 0148 5 W030 0021SC 4 3 Andirons en fonte X2 Assemblage de la barri re de protection 23 1 23 2 W660 0081 F45 F60 Thermostat...

Page 92: ...au savonneuse Le volet d air est r gl incorrectement Voir la section r glage du venturi pour le r glage de l ouverture du volet d air dans le manual d installation Du carbone se d pose sur la vitre le...

Page 93: ...lleuse Le module n est pas mis la terre Assurez le bon polarit du thermocouple si fourni V rifiez si les assemblages de le veilleuse et de la soupape sont bien mis la terre R cepteur si quip R initial...

Page 94: ...ue le r cepteur est dans la position milieu La t l commande ne fonctionne pas V rifiez les pile ainsi que leur orientation fils sont courbe s C blage de la soupape est endommag e Remplacez la soupape...

Page 95: ...les ventilateurs d vacuation les fournaises les s cheuses de linge etc Tous dommages caus s a l appareil la chambre de combustion l changeur de chaleur aux garnitures de laiton ou autres composants p...

Page 96: ...Barrie Ontario Canada L4M 0G8 214 Bayview Drive Barrie Ontario Canada L4N 4Y8 103 Miller Drive Crittenden Kentucky USA 41030 7200 Route Transcanadienne Montr al Qu bec Canada H4T 1A3 P 1 866 820 8686...