W415-4082 / A / 07.11.22
EN
34
operation (electronic)
The purpose of the turbo burner is to increase heat output of BTUs of the appliance and will only operate when
the main burner is functioning. To turn the turbo burner on, simply depress the burner control knob (located in the
valve compartment at the left hand side) and rotate the knob counter-clockwise to 'high'.
The turbo burner flame can be observed on the reflective surface in the back right corner of the firebox.
The burner flame height may now be adjusted to achieve the heat output required. Because the flame is very
efficient it will burn a very blue, almost transparent colour.
To turn off the burner, rotate the control knob clockwise to 'high'; depress the knob and turn it to off.
The on-off switch is located on the back of the appliance at the top left corner on models CDVS500-1 and CS500-
1.
This is a thermally activated switch, attached to the back of the chimney adapter, which senses the change in
temperature and shuts down the gas valve in the event of a severe downdraft of air or a blocked or disconnected
vent. It acts as a safety shut-off to prevent a build up of carbon monoxide or an explosion of unburnt gases during
start up. If the flue is blocked or has no 'draw', the spill switch will automatically shut off the supply of gas within
about 5-10 minutes.
TAMPERING WITH THE SWITCH CAN RESULT IN CARBON MONOXIDE (CO) POISONING AND
POSSIBLE DEATH.
VENTING ACTION CHECK:
A check for correct venting action must be made before the installed appliance is
left with the customer. Test in the following manner.
•
Close all doors and windows in the room / start exhaust fans in the home / turn
appliance blower off (if equipped).
•
Set controls to 'high' and light the appliance.
•
Wait 5 minutes. Light a match and extend it 1" (25mm) into the hole located
above the spill switch bracket on the adapter.
•
Venting action is satisfactory if the flame stays lit. Venting action is
unsatisfactory if the flame extinguishes.
•
If venting action is unsatisfactory, turn the appliance off, wait 10 minutes and
try again. If the match does not stay lit, turn the appliance off and check for
vent blockage or restriction. If necessary, consult with a qualified inspector.
A check for correct venting action must be made before
•
If venting action is unsatisfactory, turn the appliance off, wait 10 minutes and
8.0 operating instructions
8.1 operating instructions
8.2 turbo burner operation
8.3 spill switch - CS500-1 only