EN
W415-4082 / A / 07.11.22
5
standard checklist
1.0 general information
Installer, please fill out the following information:
Customer:
_____________________________________________________________________
Address: _____________________________________________________________________
Date of Installation:
_____________________________________________________________________
Location of Appliance:
_____________________________________________________________________
Installer:
_____________________________________________________________________
Dealer/Distributor
Contact Number:
_____________________________________________________________________
Serial
#:
_____________________________________________________________________
Model:
Natural
Gas:
Propane:
For elevations between 2,000ft (610m) and 4,500ft (1372m) above sea level, this appliance must be
de-rated by 10% using the certified high altitude kit. When the appliance is installed at elevations above 4,500ft
(1372mm), and in the absence of specific recommendations from the local authority having jurisdiction, the
certified high altitude input rating shall be reduced at the rate of 4% for each additional 1,000ft (305m).
Change in flame appearance from "HI" to "LO" is more evident in natural gas than in propane. Expansion /
contraction noises during heating up and cooling down cycles are normal and to be expected.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified kit is used.
Vented decorative gas appliance: not a source of heat; not for use with solid fuel.
CDVS500-1:
This appliance is approved for bathroom, bedroom and bed-sitting room installations and is
suitable for mobile homes. The natural gas model is suitable for installation in a mobile home that is permanently
positioned on its site and fueled with natural gas.
CS500-1:
This appliance is approved for bedroom and bed-sitting room installations.
CS500-1
CDVS500-1
NG
P
NG
P
Altitude (FT)
0-2000
Max. Input (BTU/HR)
44,000
40,000
44,000
40,000
Max. Output Steady State (BTU/HR)
31,200
30,000
33,000
30,400
Min. Inlet Gas Supply Pressure
4.5" (11mb)
Water Column
11" (27mb)
Water Column
4.5" (11mb)
Water Column
11" (27mb)
Water Column
Max. Inlet Gas Supply Pressure
7" (17mb)
Water Column *
13" (330.2mm)
Water Column
7" (17mb)
Water Column
13" (330.2mm)
Water Column
Manifold Pressure (Under Flow
Conditions)
3.5" (9mb)
Water Column
10" (25mb)
Water Column
3.5" (9mb)
Water Column
10" (25mb)
Water Column
note:
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the appliance and
must be installed.
1.1 rates and efficiencies
* Max. inlet pressure not to exceed 13".
CDVS500-1NEA
CS500-1NEA
CDVS500-1PEA
CS500-1PEA