WATER INLET
WATER INLET AND ELECTRONIC LEVEL CONTROL
For the initial filling of the boiler; as soon as the water comes into contact with the safety sensor (3), the
immersion heater automatically heats up.
If, during use, the water falls below this level (3), the machine automatically switches to standby mode.
As soon as the water falls below the automatic level sensor (2), the electronic controller (5) commands
the solenoid valve (4) to allow the refill of the boiler (1).
A non-return valve (6), stops pressurized water from returning up the water supply pipe, if the water
supply is cut off.
1
Chaudière
Boiler
2
Sonde de Niveau
Automatic Level Sensor
3
Sonde de Sécurité
Safety Sensor
4
Electrovanne
Solenoid Valve
5
Centrale Electronique
Electronic Controller
6
Clapet Anti Retour
Non Return Valve
Water