background image

 MQS4432/1017

WARRANTY/DISCLAIMER

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 

13 months

 

from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal 

one (1) year product 

warranty

 to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product.

If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department will issue an 

Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to 

be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action 

of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper 

repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows 

evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specifica-

tion; misapplication; misuse or other operating conditions outside of OMEGA’s control. Components in which wear is not war-

ranted, include but are not limited to contact points, fuses, and triacs.

OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes respon-

sibility for any omissions or errors nor assumes liability for any damages that result from the use of its products 

in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts 

manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES 

OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL 

IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are 

exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negli-

gence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which 

liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages.

CONDITIONS:  Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a “Basic Component” under 10 

CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any 

Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, 

OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will 

indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in 

such a manner.

FOR 

WARRANTY

 RETURNS, please have the following infor-

mation available BEFORE contacting OMEGA:
1.  Purchase Order number under which the product was 

PURCHASED,

2.  Model and serial number of the product under warranty, and
3.  Repair instructions and/or specific problems relative to the 

product.

FOR 

NON-WARRANTY

 REPAIRS, consult OMEGA for current 

repair charges. Have the following information available BEFORE 

contacting OMEGA:
1. Purchase Order number to cover the COST of the repair,
2. Model and serial number of the product, and
3.  Repair instructions and/or specific problems relative to the 

product.

OMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and 

engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2017 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic 

medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

RETURN REQUESTS / INQUIRIES

Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY 

PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA’S CUSTOMER 

SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the 

outside of the return package and on any correspondence.
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit.

Servicing North America:

U.S.A.  

Omega Engineering, Inc. 

Headquarters:  

Toll-Free: 1-800-826-6342 (USA & Canada only) 

 

Customer Service: 1-800-622-2378 (USA & Canada only) 

 

Engineering Service: 1-800-872-9436 (USA & Canada only) 

 

Tel: (203) 359-1660 

Fax: (203) 359-7700 

 

e-mail: [email protected] 

 

 
 

For Other Locations Visit omega.com/worldwide

omega.com   [email protected]

The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the 

right to alter specifications without notice.

Summary of Contents for UWTC Series

Page 1: ...used 1 as a Basic Component under 10 CFR 21 NRC used in or with any nuclear installation or activity or 2 in medical applications or used on humans Should any Product s be used in or with any nuclear...

Page 2: ...ConnectorTM Wireless Thermocouple RTD Connector Transmitter Receiver e mail info omega com For latest product manuals www omegamanual info Shop online at omega com For complete product manual www ome...

Page 3: ...1 Introduction 1 Section 2 Product Labels 2 Section 3 Setup Instructions 3 Section 4 Product Labels 5 Section 5 Transmitter Operation 6 Section 6 Connector Operation 7 Section 7 Battery Installation 9...

Page 4: ...Setup Instructions 3 UWTC UWRTD Setup Procedure 3 1 Install Software 3 2 Install USB Drivers 3 3 Configure Transmitter 3 4 Configure Receiver 4 Section 4 Software 5 Section 5 Transmitter Connector Op...

Page 5: ...and can transmit simultaneously with your UWTC unit Never install UWTC connector transmitters within 20 cm or less from each other Never install and or operate your UWTC connector transmitter closer...

Page 6: ...ved including interference that may cause undesired operation FCC ID OUR XBEEPRO IC 4214A XBEEPRO omega com PATENTS PATENTS PENDING F WIRELESS INDUSTRIAL TRANSMITTER 2 4 GHz OMEGA ENGINEERING INC Stam...

Page 7: ...his is normal You should repeat the steps outlined here twice After the second driver is installed you should then get the New Hardware Ready For Use notice 3 Configure Transmitter Complete the follow...

Page 8: ...r receivers complete the following procedure Your UWTC REC receiver must be connected to a USB port on your PC a Launch the UWTC REC setup utility program on your PC You can access it through the Prog...

Page 9: ...g that is being measured by your thermocouple or RTD sensor Ambient This is the actual ambient temperature connector inside the body of your Connector Transmitter If the unit is exposed to temperature...

Page 10: ...TOR LOW BATT PRESS SETUP PRESS ON OFF UWRTD 3 2 4 1 7 5 6 8 1 RTD WIRING DETAIL 2 3 4 TX UNIVERSAL WIRELESS THERMOCOUPLE CONNECTOR LOW BATT PRESS SETUP PRESS ON OFF UWTC 3 2 4 1 7 5 6 8 1 ON OFF Butto...

Page 11: ...NB9 UWTC NB9 NEMA UWTC 2 NEMA Thermocouple Version Industrial Probe RTD Versions UWRTD NB9 UWRTD NB9 NEMA UWRTD 2 NEMA RTD Version TC INPUT NOT USED TC INPUT 3 4 5 6 1 2 3 4 5 6 1 2 RTD WIRING DETAIL...

Page 12: ...will blink one time every 5 seconds 2 Low Battery Low Batt Red Indicator Light The red indicator light marked Low Batt on the front of the connector transmitter will turn on when the battery reaches...

Page 13: ...o screws that secure the main circuit board from the probe head assembly B Tilt the front of the circuit board just high enough to allow you to unplug the connector that attaches the battery assembly...

Page 14: ...ce that may cause undesired operation FCC ID OUR XBEEPRO IC 4214A XBEEPRO F 2 3 1 1 2 3 4 5 6 7 8 9 UWTC RPT1 SIDE VIEW ANTENNA USB I O 12 16 Vdc UWTC SERIES WIRELESS TRANSCEIVER OMEGA ENGINEERING INC...

Page 15: ...de in USA Omega Engineering Inc Stamford CT 06907 4 5 POWER TRANSMIT NETWORK LINK ACTIVITY 6 3 2 2 1 UWTC REC3 1 Antenna 2 Indicator Lights 3 Power LED 4 DC Power Jack 5 Reset 6 Ethernet Connection RJ...

Page 16: ...device must accept any interference received including interference that may cause undesired operation FCC ID OUR XBEEPRO IC 4214A XBEEPRO 4 UWTC REC1 NEMA 1 Antenna 2 USB NEMA 4X Connector Sealing Ca...

Page 17: ...nk each time the receiver receives incoming data from one of your connector transmitters 3 Standby SB Yellow Indicator Light The yellow indicator light marked SB on the front of the receiver will blin...

Page 18: ...3 ANALOG OUTPUT 2 ANALOG OUTPUT 1 ANALOG OUTPUT 4 ANALOG OUTPUT 3 ANALOG OUTPUT 2 ANALOG OUTPUT 1 RX PWR STATUS 1 2 3 4 5 6 7 8 10 9 8 7 6 5 4 3 2 1 Analog Output Connections 1 2 3 4 5 6 7 8 10 9 8 7...

Page 19: ...A MAX 1N4004 RX PWR STATUS Alarm Example System Powered 1 2 3 4 5 6 7 8 10 9 8 7 6 5 4 3 2 1 12 24 Vdc POWER SUPPLY 0 24 Vdc POWER SUPPLY ALARM RELAY 200 mA MAX 1N4004 RX PWR STATUS Alarm Example Exte...

Page 20: ...UIRED FOR MAGNETIC RELAYS NOT REQIRED FOR FOR SOLID STATE RELAYS OR MAGNETIC RELAYS WITH INTERNAL DIODE 0 24 VDC POWER SUPPLY 8 7 6 4 5 3 2 1 9 DRIVING A HIGH IMPEDANCE INPUT PULL HIGH DRIVE LOW J4 HI...

Reviews: