MONTE-CARLO - 11/2015 - SOFT V 2.11
6
4.6 Water softeners
When the mains water has a high hardness (>10°TH ou >4 °KH), it is recommanded:
o
To use a water treatment
o
To regenarate regularly the filters.
What is the total Hardness of the water ?
o
This is the amount of calcium and magnesium ions in the water.
o
These ions are partly responsible for limestone formation.
o
It is measured with the test strip provided with the machine.
o
The unit of measurement is the ° French (° TH) or the ° German (° dH).
What is the Karbonat Hardness of the water?
o
This is the amount of Carbonate Calcium ions and Carbonate Magnesium ions in the
water.
o
These ions are completely responsible for limestone formation.
o
It is measured with chemical dropper testers.
o
The unit of measurment is ° Carbonate (°KH)
There are 2 types of water treatments:
Salt water softeners
o
They treat the total water hardness (°TH)
o
By an exchange of sodium ions with calcium and magnesium ions.
o
They require periodic regeneration of the resins by the user.
o
To use when the water hardness is > à 10°TH or > 5 °GH
Resins filters :
o
They treat the Carbonat hardness water (°KH)
o
By fixing carbonate ions on the resins.
o
Often fitted with microfiltration and carbon filtration.
o
To use when the Carbonat Hardness is > à 6°KH
o
Highly recommended by the manufacturer :
The machines are equipped with suitable protection in accordance with flowrate
and the water encountered.
The changing cartridges is carried out by the technical service, at intervals to
be determined
Summary of Contents for MONTE-CARLO
Page 1: ...MONTE CARLO 11 2015 SOFT V 2 11 1 TECHNICAL DOCUMENTATION...
Page 46: ...MONTE CARLO 11 2015 SOFT V 2 11 46 17 ELECTRIC DRAWING 17 1 CPU board...
Page 47: ...MONTE CARLO 11 2015 SOFT V 2 11 47 17 2 Electrical power diagram for 400V 3L N PE...
Page 48: ...MONTE CARLO 11 2015 SOFT V 2 11 48 17 3 Electrical power diagram for 230 V 1L N PE...
Page 49: ...MONTE CARLO 11 2015 SOFT V 2 11 49 17 4 Connecting diagram 12 fuses box...
Page 50: ...MONTE CARLO 11 2015 SOFT V 2 11 50...
Page 51: ...MONTE CARLO 11 2015 SOFT V 2 11 51...
Page 52: ...MONTE CARLO 11 2015 SOFT V 2 11 52...
Page 53: ...MONTE CARLO 11 2015 SOFT V 2 11 53 17 5 Solid state relay interface for 400 V 3NAC...
Page 54: ...MONTE CARLO 11 2015 SOFT V 2 11 54 17 6 Low voltage wiring...
Page 55: ...MONTE CARLO 11 2015 SOFT V 2 11 55 18 HYDRAULIC SCHEME...