MONTE-CARLO - 11/2015 - SOFT V 2.11
57
19
ALARM
CODE
Description
Faults
Recommandations
A01
Coffee boiler 1 probe alarm
- Coffee boiler 1 t° probe in
short-circuit or
disconnected.
- Check the probe
- Check the probe connection
- Check the electronic board
A03
Coffee boiler 2 probe alarm
- Coffee boiler 2 t° probe in
short-circuit or
disconnected.
- Check the probe
- Check the probe connection
- Check the electronic board
A05
Coffee boiler 3 probe alarm
- Coffee boiler 3 t° probe in
short-circuit or
disconnected.
- Check the probe
- Check the probe connection
- Check the electronic board
A09
Group 1 probe alarm
- Group 1 t° probe in short-
circuit or disconnected.
- Check the probe
- Check the probe connection
- Check the electronic board
A11
Group 2 probe alarm
- Group 2 t° probe in short-
circuit or disconnected.
- Check the probe
- Check the probe connection
- Check the electronic board
A13
Group 3 probe alarm
- Group 3 t° probe in short-
circuit or disconnected.
- Check the probe
- Check the probe connection
- Check the electronic board
A15
A17
Boiler probe alarm
- Boiler t° probe in short-
circuit or disconnected.
- Check the probe
- Check the probe connection
- Check the electronic board
A19
Steam control probe alarm
- Steam control t° probe in
short-circuit or
disconnected.
- Check the probe
- Check the probe connection
- Check the electronic board
A22
Safety probe alarm
(low level)
- Low level safety probe
didn’t detect water for more
than 2 seconds => boiler
heating stopped
- Check the probe (limestone)
- Check the probe connection
- Check the electronic board
- Check that the boiler fills
- Check the water inlet
A23
Boiler time out alarm
- Time allocated to the
boiler heating exceeded.
- Check the boiler t° probe
- Check the probe connection
- Check the electronic board
- Check the heaters and the relays
- Check the programmed heating time
- Check the relay control box
A24
Coffee boiler 1 time out alarm
- Time allocated to the
coffee boiler 1 heating
exceeded.
- Check the t° probe
- Check the probe connection
- Check the electronic board
- Check the heater and the relay
- Check the programmed heating time
- Check the relay control box
A25
Coffee boiler 2 time out alarm
- Time allocated to the
coffee boiler 2 heating
exceeded.
- Check the t° probe
- Check the probe connection
- Check the electronic board
- Check the heater and the relay
- Check the programmed heating time
- Check the relay control box
A26
Coffee boiler 3 time out alarm
- Time allocated to the
coffee boiler 3 heating
exceeded.
- Check the t° probe
- Check the probe connection
- Check the electronic board
- Check the heater and the relay
- Check the programmed heating time
- Check the relay control box
A27
Flow meter 1 time out alarm
- No flowmeter 1 pulse after
5 seconds
- Check the flowmeter (flashings)
- Check the flowmeter connection
- Check the electronic board
- Check for clogged coffee group
Summary of Contents for MONTE-CARLO
Page 1: ...MONTE CARLO 11 2015 SOFT V 2 11 1 TECHNICAL DOCUMENTATION...
Page 46: ...MONTE CARLO 11 2015 SOFT V 2 11 46 17 ELECTRIC DRAWING 17 1 CPU board...
Page 47: ...MONTE CARLO 11 2015 SOFT V 2 11 47 17 2 Electrical power diagram for 400V 3L N PE...
Page 48: ...MONTE CARLO 11 2015 SOFT V 2 11 48 17 3 Electrical power diagram for 230 V 1L N PE...
Page 49: ...MONTE CARLO 11 2015 SOFT V 2 11 49 17 4 Connecting diagram 12 fuses box...
Page 50: ...MONTE CARLO 11 2015 SOFT V 2 11 50...
Page 51: ...MONTE CARLO 11 2015 SOFT V 2 11 51...
Page 52: ...MONTE CARLO 11 2015 SOFT V 2 11 52...
Page 53: ...MONTE CARLO 11 2015 SOFT V 2 11 53 17 5 Solid state relay interface for 400 V 3NAC...
Page 54: ...MONTE CARLO 11 2015 SOFT V 2 11 54 17 6 Low voltage wiring...
Page 55: ...MONTE CARLO 11 2015 SOFT V 2 11 55 18 HYDRAULIC SCHEME...