3. External Connection
32
CNT-3204MT-LPE
*1: The pull-up pins are PUP1 for the counter input signal and PUP2 for the control input signal.
Figure 3.6. Connection when it is pull-up by internal 3.3-V output power (Counter Input)
Figure 3.7. Input signal
-
The connection cable length should be within 1.5 m.
-
To prevent noise from causing a malfunction, arrange the connection cable as away from any
othersignal conductor or noise source as possible.
-
Please use the shielded cable to meet “CE EMC Directive”.
t
PWL
t
PWH : High-level count input pulse width 50nsec (Min.)
t
PWL : Low-level count input pulse width
50nsec (Min.)
t
PWH
CAUTION