![Contec AD12-16(PCI) User Manual Download Page 39](http://html1.mh-extra.com/html/contec/ad12-16-pci/ad12-16-pci_user-manual_2655852039.webp)
Functions and Operating Procedures
AD12-64(PCI), AD12-16(PCI)
32
Figure 4.1. Basic operation for analog input
Sampling operation is verified by
monitoring status. Generating an
interrupt by status change is allowed
also. Figure 4.2. shows procedures for
inputting analog signals. Perform
initialization before starting sampling.
Then specify sampling conditions, such
as mode of operation and input range.
Output the start command to feed the
data for conversion.
Figure 4.2.
Analog input procedures
1ch
1ch
3ch
2ch
1ch
0ch
3ch
2ch
1ch
0ch
sampling start
input channel
3ch
1ch
sampling start
input channel
3ch
2ch
1ch
0ch
3ch
2ch
1ch
0ch
b. Software mode - Multichannel mode
a. Software mode - Single channel mode
sampling start
input channel
sampling clock
sampling clock
sampling start
input channel
c. Clock mode - Single channel mode
d. Clock mode - Multichannel mode
Start
Initialization
Specify sampling
conditions
Start sampling
Specify input range
Input data
End
Summary of Contents for AD12-16(PCI)
Page 1: ...AD12 64 PCI AD12 16 PCI 64 16 Channel Analog to Digital Input Board for PCI User s Guide...
Page 61: ...Functions and Operating Procedures AD12 64 PCI AD12 16 PCI 54...
Page 67: ...Calibration Procedures AD12 64 PCI AD12 16 PCI 60...
Page 71: ...System Reference AD12 64 PCI AD12 16 PCI 64...
Page 74: ...Index AD12 64 PCI AD12 16 PCI...
Page 75: ...A 46 068 LZJ3711 021011 991104...