Investigative Authority Guide
54
1
0062-00A01
3
Other equipment:
•
Standard Ethernet (CAT 5E) cable and passwords are needed.
•
For L3 capsule: Software L3HVRReader.exe
Special software is needed for replaying the data:
-
Consilium Voyage Data Professional Player (VDPP) is available for
downloading from sent out CD, or
-
Consilium Voyage Data Analyzing Player (VDAP) can be ordered from
Consilium Navigation AB.
For detailed information of the Voyage Data Player (VDP) see Professional Player Guide.
1.4 VDR
memory functions
The VDR automatically records and stores data on the Capsule according to IMO
Resolution A.861(20), MSC.214(81) and IEC 61996-1 for VDR and IEC 61996-2 for S-
VDR Such data is stored for 12 hours (optionally longer), and is then automatically over-
written by new data. The VDR also records data to an USB memory stick placed behind
the locked door in Main Unit. In order to safely remove the USB memory stick follow the
Accident/Incident
Backup procedure
(see User Information). That data will be saved on
the USB memory stick until it is removed and put back again.
Recorded and saved data can be downloaded to a PC (Laptop) in different ways:
1.
Directly from the capsule it self, after capsule and/or data storing function has been
exposed to a destroying accident (see 2.1).
2.
By after a backup procedure removing the USB memory stick placed in the Main
Unit and copying it (see 2.2).
3.
From the capsule connected to the VDR Main Unit via an Ethernet output (see
2.3).
4.
From USB stick via Ethernet output.
Optionally other connected input sources can also be recorded, i.e. other radar-, ECDIS-,
conning-displays, ITV, etc. Such data are normally not stored on the capsule memory, but
on other internal or external e.g. on a Portable Black Box (PBB).