7. V (+) input bush (= plus connection) for the remaining measurements
8. IR interface on the casing's underside
9. Battery compartment
Index
Page
Introduction2
Use as in accordance with the requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Operating elements (fold-out page) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Safety advice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Pre-positioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Handling and commissioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Carrying out measurements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Correcting faults. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Maintenance and care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Technical data and measuring tolerances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Safety advice
The guarantee is invalidated if the operating instructions are not heeded! We do not
accept any liability for consequential loss resulting from such action. We are not lia-
ble for damage to property or personal injury which has been caused by improper
handling or non-observance of the safety advice. Such cases invalidate any claim to
the guarantee.
• This equipment has been manufactured and tested according to part 1 of the Ger-
man standard DIN 57 411/VDE 0411 part 1 'Protective measures for electronic
measuring devices' and IEC 1010-1. It has left the factory in a perfectly safe con-
dition. In order to maintain this condition and to ensure safe operation, the user
must observe the ('attention' and 'advice') safety advice and warning notices,
which are contained in these instructions for use. The following symbols must be
observed:
35
Maximale Eingangsgrößen, Überlastschutz
Spannungsmessung . . . . . . . . . . .: 1000 VDC bzw. 750 VACrms
max. 250 VDC bzw. VACrms im mV-Bereich
Strommessung . . . . . . . . . . . . . . .: 10 A AC/DC im A-Bereich, max. 3 Min. lang
mit einer anschließenden Abkühlphase von
mind. 15 Min. max. 600 VDC/VACrms,
Überlastschutz: Super-Flinke 15-A-600-V-
Sicherung, Typ: High Energy
5 / 500mA AC/DC im uA/mA-Bereich,
max. 600 VDC/VACrms,
Überlastschutz: Super-Flinke 1-A-600-V-
Sicherung Typ: High Energy
Widerstandsmessung . . . . . . . . . .: 50 MOhm, Überlastschutz : 250 V DC/ACrms
Zener-Diodentest . . . . . . . . . . . . . .: Überlastschutz 250 V DC/ACrms
Temperaturmessung . . . . . . . . . . .: Überlastschutz 250 V DC/ACrms
Kapazitätsmessung . . . . . . . . . . . .: Überlastschutz 250 V DC/ACrms
Frequenzmessung . . . . . . . . . . . . .: Überlastschutz 250 V DC/ACrms
Eine Überschreitung der max. zulässigen Eingangsgrößen führt
unter ungünstigen Umständen zur Beschädigung des Meßgerätes
bzw. zu einer Gefährdung des Lebens des Benutzers.