8. Preparation for operation
You can supply the device either with 3 batteries type mignon/ AA or stabilised
direct current between 5V and 24V. As already mentioned in chapter 7, the output
of the connected power pack unit may not exceed 15W.
The voltage source is selected with the jumper "J2".
Battery supply
If you want to operate the "FS20 TC6" with batteries, plug the jumper "J2" in
position "Bat". Insert 3 batteries type AA/mignon observing the correct polarity
(observe plus/+ and minus/-).
External voltage supply
You my have to remove the inserted batteries for external voltage supply. Then
plug the jumper "J2" in position "Ext". Connect a stabilised direct voltage source
between 5V and 24V to the 2-pole screw clamp "KL1", plus/+ and minus/- is
indicated on the circuit board next to the screw clamp.
In case of wrong polarity or using an unsuitable voltage supply, the
"FS20 TC6" will be destroyed. Loss of warranty/guarantee!