Technical Data

Operating voltage ......................230 V/AC, 50 Hz
Protection class .........................I
Protection type ...........................IPx8
Nominal output ..........................38 W
Connection cable .......................H05RN-F, 3 x 0,75 mm², length app. 10 m  
Delivery lift .................................max. 1,9 m above the intake port
Flow rate ....................................up to 1400 l/h
Temperature of water .................max. +35 °C
Hose diameter ...........................1.27 cm (1/2”)
Dimensions ................................115 x 190 mm (Ø x H)
 

(max. height with extension tube and spraying nozzle 470 mm)

Weight .......................................App. 1,9 kg (without extension tube/spraying nozzle)

  

   These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,  

D-92240 Hirschau (www.conrad.com). 

 

 All rights including translation reserved. Reproduction by any method, e.g. photocopy, micro

fi

 lming, 

or the capture in electronic data processing systems require the prior written approval by the editor. 
Reprinting, also in part, is prohibited. 

 

 These operating instructions represent the technical status at the time of printing. Changes in         
technology and equipment reserved. 

 

© Copyright 2012 by Conrad Electronic SE.

Before you put device into operation

Put the fountain pump into a shallow pond or a similar place and switch on. Through various 
nose pieces, the pumped water is sprayed out in different patterns. 
For operation, the fountain pump should be submerged in water at 30 - 40 cm depth, so that the 
extension tube and a selected nose piece would rise over the water level.

   At that, do not put the pump into bottom sludge, but use some slightly raised plat-

form.

Using the T-socket supplied with the device you can attach (if desired) another nose piece or a 
hose e.g. for watering the garden.

   Never block both shutoff valves of the T-socket, otherwise the fountain pump can be 

damaged!

A grip on the top enables to fasten the fountain pump additionally with a rope.

   Never hold or fasten the fountain pump by the mains cabel or the hose; only the grip 

on the top can be used for this purpose.

 

The fountain pump can only be operated in the upright position!

The pumped water should be clean and clear. Only 

fi

 ne suspended matter is admissible, which 

may occur in every normal garden pond. Otherwise the nose pieces will be occluded!
Coarser impurities (leaves, dirt particles, pebbles etc.) occlude the suction ports; furthermore, 
they block the pump.

Getting started

Insert the mains plug of the fountain pump to a mains socket. 
The fountain pump starts immediately and begins pumping water. 
If the water is not pumped, it can be indicative of air in the pump. Wait for few seconds or 
remove and insert the plug brie

fl

 y from the mains socket for several times.

Removing from service

Should the fountain pump be taken out of service (e.g. for cleaning, maintenance or storage in 
winter), then proceed as follows:
•   Disconnect the fountain pump from the power supply, pull the mains plug out of the mains 

socket.

•  Take the fountain pump out of the water using the carrier handle (or the fastening rope 

attached).

   Never lift the fountain pump using the hose or the mains cord! Otherwise the power 

cord may get damaged, risk of an electric shock!

•   If a hose is mounted to the fountain pump (e.g. via the T-socket), then disconnect it from the 

fountain pump.

•   Let the residual water drain out of the fountain pump holding it slantwise. 
•   Dry up the fountain pump and the power cord. If required, clean its outer surface and 

fi

 lter. 

Wind up the mains cable.

•  In winter, keep the water pump in a dry space protected against frost.

   Also do not forget to empty the hoses laid outdoor to avoid frost damages; open 

water taps if available.

•   Only the carrying handle can be used to carry the fountain pump. Never hold it using the hose 

or the mains cord.

•   A small quantity of water remains in the fountain pump after use or after the emptying opera-

tion. Therefore, when storing or transporting the pump in a vehicle, use an appropriate mat.

Maintenance and Cleaning

Before cleaning disconnect the fountain pump from the mains; remove the mains plug from 
the power socket.
Use a soft clean cloth to clean the outer surfaces of the fountain pump. If necessary rinse the 
outer surface with clear water. 
The lower part of the 

fi

 lter can be removed from the fountain pump to facilitate cleaning of the 

fi

 lter and interior parts of the pump. Only clean running water can be used for this purpose.

You can also remove the impeller. At that, before you take out the impeller, you have to over-
come certain resistance due to magnetic force.
After cleaning reassamble the fountain pump completely and properly.
Before putting in storage, dry up the fountain pump and the power cord.

   Never use abrasive cleaning agents, cleaning alcohol or other chemical solutions, 

since these can damage the housing or even impair functionality. 

Disposal

   Dispose of the unserviceable product according to the relevant statutory regulations!

Summary of Contents for 55 16 73

Page 1: ...en Au enbereich geeignet sind Sch tzen Sie die Netzleitung vor Hitze l Benzin und scharfen Kanten treten Sie nicht auf die Netzleitung befahren Sie sie nicht z B Gartenkarre Fahrrad Auto Knicken Sie d...

Page 2: ...tzsteckdose Die Springbrunnenpumpe l uft daraufhin sofort an und beginnt Wasser zu pumpen Wenn kein Wasser gepumpt wird so befindet sich m glicherweise noch Luft in der Pumpe Warten Sie einige Sekunde...

Page 3: ...H05RN F as per DIN VDE0620 Use only extension cables with protected contacts designed for outdoor applica tions Protect the cable from heat oil gasoline and sharp edges do not step on the cable do no...

Page 4: ...o a mains socket The fountain pump starts immediately and begins pumping water If the water is not pumped it can be indicative of air in the pump Wait for few seconds or remove and insert the plug bri...

Page 5: ...ouc avec le marquage H05RN F selon la norme DIN VDE0620 Utilisez des rallonges uniquement avec des prises de s curit mises la terre qui sont adapt es pour une utilisation ext rieure Prot gez le c ble...

Page 6: ...t galement les ouvertures d aspiration et bloquent ainsi la pompe Mise en service Branchez le cordon d alimentation de la pompe pour fontaine une prise secteur La pompe pour fontaine se met en marche...

Page 7: ...merk H05RN F volgens DIN VDE0620 Gebruik uitsluitend verlengkabels met randaarde die geschikt zijn voor gebruik buitenshuis Bescherm de netkabel tegen hitte olie benzine en scherpe kanten trap niet op...

Page 8: ...de pomp blokkeren Ingebruikname Steek de netstekker van de fonteinpomp in een netcontactdoos De fonteinpomp loopt aan en begint water op te pompen Als er geen water wordt gepompt dan bevindt zich wel...

Reviews: