Conrad 55 16 73 Operating Instructions Manual Download Page 3

Intended use

The fountain pump is designed for private use e.g. in hobby gardening. The product is not 
intended for irrigation or irrigation systems in the industry, production or public sectors (e.g. 
garden complexes).
Through various interchangeable nosepieces, the water delivered by the fountain pump is 
sprayed out in an optically appealing manner.
As a pumped 

fl

 uid, only clear water is acceptable (e.g. in a pond and suchlike). Never use other 

liquids (e.g. salt water, gasoline, heating oil or foodstuffs). The temperature of the pumped 

fl

 uid 

shall not 35 °C.
Read these operating instructions completely and thoroughly, as they contain a lot of important 
information about operation and handling. Observe all safety instructions!
Any other use, than that described above, could lead to damage to this product and involves a 
risk for short circuits, 

fi

 re, electric shock, etc. 

This product complies with the applicable National and European requirements. All names of 
companies and products are the trademarks of the respective owner. All rights reserved.

Package Contents

• Fountain pump
•  Various nose pieces
• Extension tube
•  A T-socket with a shut-off valve
• Operating Instructions

Safety Instructions

   The warranty will be void in the event of damage caused by failure to observe 

these safety instructions! We do not assume any liability for any consequen-
tial damage! 

 

 Nor do we assume any liability for material and personal damage caused by 
improper use or non-compliance with the safety instructions! In such cases, 
the warranty will be deemed void!

 

 Dear customer, Not only are the following safety notes and hazard warnings 
intended to protect the device, they are also intended to protect your health. Please 
read the following points carefully:

 

General

 

•   The unauthorised conversion and/or modi

fi

 cation of the product is not permitted for 

safety and approval reasons (CE). Moreover, this will invalidate the warranty!

 

•  The product is not a toy. Children are not aware of the potential dangers involved 

when using electrical devices. 

 

• The product corresponds to protection class IPx8. 

 

•   The device is designed according to safety class I. Only a properly grounded socket 

(230V/AC, 50Hz) of the public supply mains may be used as a voltage source.

 

•  Do not leave packing materials unattended. They may become dangerous play-

things for children.

 

•  Handle the product with care, it can be damaged by impacts, blows, or accidental 

drops, even from a low height. 

 

Installation site and connection

 

•  Assemble and operate the product in a way that keeps it out of reach of children.

 

•  The use of the product in the proximity of ponds, wells, swimming pools, springs 

etc. is not permitted unless the product is operated via a ground fault circuit inter-
rupter (circuit breaker FI, <=30mA).

 

   In Austria, the product is not permitted to be installed and operated in the proximity 

of swimming pools and ponds unless a safety isolating transformer controlled by 
the Austrian Electro-technical Association is additionally connected upstream to 
the ground fault circuit interrupter (circuit breaker FI, <=30mA).

 

•  In the place of installation the ambient temperature must not be around or under 

the freezing point (<0 °C). This causes the water to freeze in the fountain pump; 
the higher volume of ice destroys the fountain pump. In winter, store the product in 
a dry place above freezing point.

  •  If you use an extension cable or it is necessary to lay cables to the fountain pump, 

make sure that the cable cross section is not smaller than that of the rubber hose 
lines with short symbol H05RN-F as per DIN VDE0620. 

 

   Use only extension cables with protected contacts designed for outdoor applica-

tions.

 

•  Protect the cable from heat, oil/gasoline and sharp edges; do not step on the 

cable, do not drive over it (e.g. with a wheelbarrow, bicycle, car). Never bend the 
cables and do not place objects on them.

 

•  Ensure that connection for the electric plug is located in an area protected against 

fl

 ooding, otherwise, there is a lethal danger of an electric shock!

 

Operation

 

•  Check the product before each use for damages, e.g. of the housing, the gaskets 

and the power cord/plug.

  

 

If 

you 

fi

 nd any damage, you must not use the product. Do not attempt to repair a 

damaged mains cable! There is a risk of a life-threatening electric shock!

 

   If the product is already connected to the mains, switch off the mains at the respec-

tive socket (e.g. by turning off the circuit breaker). Furthermore, turn off the earth 
leakage circuit breaker to disconnect all the poles of the socket from the mains 
voltage.

 

   Then you can remove the power cable plug of the fountain pump from the socket. 

Afterwards, the product can no longer be used; take it to a specialist workshop.

 

  Repairs should be carried out by a specialist workshop!

 

•  If you have reasons to assume that safe use is no longer possible, put the fountain 

pump out of operation and remove the power cable plug from the mains socket to 
secure it against inadvertent operation. It must be presumed that safe operation is 
no longer possible, if:

 

  - the pump and the connecting lines show visible damages

 

  - the pump does not operate any longer,

 

  - the pump was transported or stored under unfavorable conditions.

 

  - it was exposed to heavy loads during transport.

 

•   The product is designed for the mains voltage 230 V/AC, 50 Hz of the public supply 

mains. Never use the product with a different voltage.

 

•  Always unplug the device when not in use, and before repairs, maintenance or 

cleaning.

 

•  Never remove the mains plug from the socket by pulling on the cable. Always pull 

the plug from the mains socket by gripping the lateral surfaces.

 

   Never touch the plug when your hands are damp or wet. Danger of a life-threaten-

ing electric shock!

 

• Carry the product using the carrying handle; never carry it by the power cord.

 

•  Do not block the discharge unit of the fountain pump if it is in operation. 

 

• The product is not protected against longer dry runs (> 2 Minutes). 

 • 

 

The 

pumped 

fl

 uid should be as clean as possible. Impurities (e.g. sand, earth, 

leaves etc.) cause both higher wear thus reducing the life span of the fountain 
pump and the possibility of mechanical clogging of the drive rotor and blockage of 
all intake ports. 

 

   Besides, light soiling occlude the ori

fi

 ces of the nose pieces supplied with the 

pump.

 

   Therefore, regular functional control of the fountain pump is absolutely essential.

 

• The product is not suitable for the conveyance of drinking water.

 

• Nobody is allowed to stay in the pumped 

fl

 uid during the pump operation.

 

•  Consequential damages caused by malfunction or fault of the fountain pump, 

should be prevented by relevant measures (e.g. by use of water level gauge, sen-
sors, alarm devices and suchlike).

 

•  When the product is taken from a cold to a warm room (e.g., during transport), 

condensate may form. Thus a danger to life through electric shock may occur 
when the cable is plugged to the mains!

 

   This is why always let the product get to room temperature before you use it or 

connect it to the mains voltage. This may take several hours. 

 

• The product is only suitable for use in temperate, not tropical, climates.

 

•  Do not leave packing materials unattended. They may become dangerous play-

things for children.

 

   O P E R A T I N G   I N S T R U C T I O N S   www.conrad.com

Fountain pump, stainless steel

 Item no. 55 16 73

 Version  03/12

Summary of Contents for 55 16 73

Page 1: ...en Au enbereich geeignet sind Sch tzen Sie die Netzleitung vor Hitze l Benzin und scharfen Kanten treten Sie nicht auf die Netzleitung befahren Sie sie nicht z B Gartenkarre Fahrrad Auto Knicken Sie d...

Page 2: ...tzsteckdose Die Springbrunnenpumpe l uft daraufhin sofort an und beginnt Wasser zu pumpen Wenn kein Wasser gepumpt wird so befindet sich m glicherweise noch Luft in der Pumpe Warten Sie einige Sekunde...

Page 3: ...H05RN F as per DIN VDE0620 Use only extension cables with protected contacts designed for outdoor applica tions Protect the cable from heat oil gasoline and sharp edges do not step on the cable do no...

Page 4: ...o a mains socket The fountain pump starts immediately and begins pumping water If the water is not pumped it can be indicative of air in the pump Wait for few seconds or remove and insert the plug bri...

Page 5: ...ouc avec le marquage H05RN F selon la norme DIN VDE0620 Utilisez des rallonges uniquement avec des prises de s curit mises la terre qui sont adapt es pour une utilisation ext rieure Prot gez le c ble...

Page 6: ...t galement les ouvertures d aspiration et bloquent ainsi la pompe Mise en service Branchez le cordon d alimentation de la pompe pour fontaine une prise secteur La pompe pour fontaine se met en marche...

Page 7: ...merk H05RN F volgens DIN VDE0620 Gebruik uitsluitend verlengkabels met randaarde die geschikt zijn voor gebruik buitenshuis Bescherm de netkabel tegen hitte olie benzine en scherpe kanten trap niet op...

Page 8: ...de pomp blokkeren Ingebruikname Steek de netstekker van de fonteinpomp in een netcontactdoos De fonteinpomp loopt aan en begint water op te pompen Als er geen water wordt gepompt dan bevindt zich wel...

Reviews: