DX-1S Digital PABX - Programming Manual
5-8
5.1.31 PROGRAMMING ITEM 30 : NO. OF DIGITS USING TIMEOUT A
This item is to define how many digits is applied with Trunk Dialing Timeout A in outgoing call.
Command
3 * 30 * Value <Enter>
where Value = 1 ~ 24 (no. of digits)
Default Value
Default = 3 (the first three digits)
Related Topic
1.
Programming Item 28 - Trunk Dialing Timeout A
2.
Programming Item 29 - Trunk Dialing Timeout B
5.1.32 PROGRAMMING ITEM 31 : PRE-DIGIT PAUSE OF SPEED DIALING
This item is to set the pause duration before sending the first dialing digit to public exchange from the
system trunk interface in Speed Dialing and Last Number Redial.
Command
3 * 31 * Value <Enter>
where Value = 1 ~ 25 (seconds)
Default Value
Default = 1 (seconds)
5.1.33 PROGRAMMING ITEM 32 : INCOMING TRUNK CALL RINGING TIMEOUT
The system will assume the incoming trunk call ringing has terminated if the trunk interface cannot
detect the ringing within the Incoming Trunk Call Ringing Timeout duration. The appropriate timeout
value should be set about 1 second longer than the longest “off” time of the central office ringing pattern.
Command
3 * 32 * Value <Enter>
where Value = 1 ~ 25 (seconds)
Example
1.
If the ringing pattern of central office is 0.4s on, 0.2s off, 0.4s on, 4s off, the longest "off" time is 4
seconds. So, the appropriate time for Incoming call timeout is 5 seconds. Command is 3 * 32 * 5.
Condition
1.
If the setting is too short, the system will wrongly stop ringing before the second ringing cycle come.
2.
If the setting is too long, the system will keep on ringing until timeout even the caller had hanged up
the handset.
Default Value
Default = 5 (seconds)
5.1.34 PROGRAMMING ITEM 33 : TRUNK RELEASE DELAY
Once a trunk call has terminated, the system will release the trunk line immediately but will not allow
other extension to get the trunk line within Trunk Release Delay Timeout. It will prevent an extension to
get a trunk line which is not yet terminated in last call.
Command
3 * 33 * Value <Enter>
where Value = 1 ~ 25 (seconds)
Default Value