Operation Manual
Track Supply 6 kW
80 / 125 A at 400 / 480 V
BAL9100-0124c-EN
www.conductix.com
Page 18 of 44
7.2.3
Modes of Operation
During operation the LCD provides basic information about the operating mode of the Track Supply. The following modes have
been defined:
The Track Supply is powered but does not receive a high level signal on its RESET
input. Output is disabled.
The Track Supply is powered but does not receive a high level signal on the START
input. Output is disabled.
The Track Supply is operating normally.
The Track Supply detected an error. Error code with time and date of occurrence are
displayed. Refer to section 7.2.6 below for details on error codes
Output is disabled.
7.2.4
Setting Language, Time and Date
There are two buttons located beneath the LCD that allow the user to change basic settings. Settings may be changed in any
mode, except in RESET mode. If the RESET mode is entered (RESET input low) while settings are being changed, any changes
made are lost!
To start changing settings, the MODE key must be held down for 5 seconds. Once
this delay has expired the right hand screen will be displayed. Subsequent presses of
the SET key will step through the four available display languages:
•
English
•
German
•
French
•
Italian
Pressing the MODE key will advance to the next setting screen shown below.
The time setting is displayed in 24 h hh:mm format. The keys function as follows:
•
Pressing or holding the SET key will increase the setting marked by the cursor.
•
Pressing the MODE key will advance the cursor to the minute setting or the next
screen respectively.
SET TIME
1
5
:01
hh:mm
SELECT LANGUAGE
English
-----ERROR------
E001 15:01
26.05.09
------RUN-------
No warnings
----STANDBY-----
No warnings
-----RESET------
No warnings