Mounting and installation work
Connecting the control voltage
Note: if the Condair RS is equipped with option "CVI" or "TR", a separate control voltage supply is
not required.
MAINS SUPPLY
L N SC1SC2 PEPE
L1 N PE
F4
Q4
230 V/1~/50..60 Hz
Control compartment
The control voltage supply (L1, N, PE) is to be con-
nected in accordance with the wiring diagram to the
corresponding terminals on the driver board in the
control compartment.
The installation of the
fuse" F4"
(10A, slow acting) and
the
electrical isolator "Q4"
(all pole disconnecting
device with a minimum contact clearance of 3 mm, sup-
plied by others) in the mains supply line are mandatory.
The electrical isolator must be mounted in direct prox-
imity of the control compartment (max. distance 1 m)
and must be easily accessible in a height between 0.6
m and 1.9 m (recommended: 1.7 m) .
CAUTION!
Make sure the voltage indicated on the
specification label meets the local mains voltage. Oth-
erwise, do not connect the unit.
The cross-section of the cable must comply with the
applicable local regulations (minimum of 1.5 mm
2
).