Page
27
of
30
7.2 THERMAL CUT OUT (TCO) RESET
WARNING
Be aware of high voltage in
the block area. The
electrical supply should be
switched off before working
in the heater block
compartment.
CAUTION
If the Smoke Screen has
been in service the heater
block and connected parts
will be extremely hot and will
cause injury if touched.
Therefore, the Smoke
Screen should be switched
off and time should be
allowed for the heater block
to cool.
The TCO can be reset using the following procedure:
•
Make sure the mains power to the machine is turned off before resetting the TCO.
•
Reset the TCO by pressing on the little button on the top area. If the thermal device has
tripped it should be possible to hear a click when it resets.
•
Switch on the mains power after resetting.
•
Check the machine heats up to normal operating temperature and make sure it archives a
ready state. See the operating “LCD, LED and Sound Indications” for further information on
fault indications.
Note: The position of the
TCO
can be different depending on the machine version. The location
pictured is for an TI70/TI100 HW V6.
Summary of Contents for Titanium TI100