Menu Item
Sub-menu item
Delivery setting
Description
Mbus Mode
CCS Slave
RS485 configuration. SSM can be configured as Master, CCS Slave or Slave 1-9. When
configured as Master, options become available to propagate SNMP (remote) triggers to
the chain, propagate panic inputs from any point to the whole chain and propagate hold off
inputs from any point to the whole chain. Refer to RS485 section 5.7.2 for further
information.
Top up life cycle
30 minutes
Limits top up operations by time. When a Screen Sensor is used on Z3, this setting will
cause the SSM to ignore further inputs from the Screen sensor after the timer has expired.
The timer begins
after
the first cycle of fog production i.e. if the “Smoke on” time is set to 2
minutes, the top up life cycle commences after 2 minutes.
Top up % time
25%
Sets top up operation as a % of “Smoke on time”. If the Screen sensor detects a drop in
fog density, the SSM will operate according to how this is set.
Smoke on time
01min 00 sec
Sets duration of first burst. Timer only runs when fog is being actively produced. Rest
phases are ignored.
Panic smoke time
01min 00 sec
Sets duration of Panic smoke time. Timer only runs when fog is being actively produced.
Rest phases are ignored.
Hold off
on
Enables hold-off retriggering. When “Smoke on” timer expires, and an intruder condition
still exists, if the hold-off reactivates, the SSM will re-trigger according to the sub-menu
settings.
Hold off time
25%
Item available if Hold off set to "On". Can be set between 0 and 100% in 1% intervals.
Sets the re-triggering activation time as a % of the set “Smoke on” time.
Hold off rep nr
10
Item available if Hold off set to "On". Can be set between 0 and 50 in 1 unit intervals.
Sets the number of times time that the SSM will retrigger when the hold-off reactivates.
Smoke Delay
00 min 00 sec
Sets the time the Smoke Screen will wait after an activation demand before producing
smoke. Can be set between 0 and 2 minutes in 1 second intervals.
(Z1) Set Input
Normally closed
Defines the type of input the Smoke Screen requires to sense an Alarm Set state.
Settings available are “Normally closed”, “Normally open”, a range of EOL resistance
settings or “Not used”. Stops all activations except panic.
(Z2) Trigger Inp
Normally closed
Defines the type of input the Smoke Screen requires to sense a Trigger alarm Settings
available are “Normally closed”, “Normally open”, a range of EOL resistance settings or
“Not used”.
(Z3) Top-up Detec
Normally closed
Defines the type of input the Smoke Screen requires to sense an alarm state for the Top-
up detector (Screen Sensor). Settings available are “Normally closed”, “Normally open”, a
range of EOL resistance settings or “Not used”.