Page
22
of
30
Menu Item
Sub-menu item
Delivery setting
Description
(Z4) Hold-Off Inp
Normally closed
Defines the type of input the Smoke Screen requires to sense a hold off alarm. Settings
available are “Normally closed”, “Normally open”, a range of EOL resistance settings or
“Not used”.
(Z5) Panic Trig.
Normally closed
Defines the type of input the Smoke Screen requires to sense a panic alarm state.
Settings available are “Normally closed”, “Normally open”, a range of EOL resistance
settings or “Not used”. This input ignores the condition of all other inputs. A panic input will
trigger the generator for the set “Panic smoke” time.
(Z6) Isolate
Normally closed
Defines the type of input the Smoke Screen requires to be isolated by this input. Settings
available are “Normally closed”, “Normally open”, a range of EOL resistance settings or
“Not used”.
PGM 1/2/3 output*
Normally closed
Sets the state of the PGM Outputs. Settings available are “Normally closed” and “Normally
open”
PGM 1/2/3 function*
Disabled
Settings "Disabled", “Iris mode”, "Follow Trouble", "Follow Run Dry", "Follow Isolate", "Aux
timer", "Follow Zone"
PGM Z1-6
Z1-6=Disabled
Used to select which of the zones will trigger the PGM when the machine is in Iris mode
and the respective zone changes state. The Up arrow scrolls through the zones and the
down arrow selects between “enabled” and “disabled”. Enter saves the setting
Zone number 0>0
Used to set the required Zone (1 to 5) if "Follow Zone" selected.
PGM Timer
1 sec
Set the time between 0 and 120 minutes in 1 second intervals that the PGM will change
state if "Timer Relay" selected.
Entry/exit time
00 min 00 sec
Set the time between 0 and 3 minutes in 1 second intervals that the Smoke Screen will
ignore activation demands after the Alarm Panel sets the Alarm Set (Z1) input.
Energy Save Mode
off
Enables or disables the ESM. Settings available are "Off" (disabled), "On" (lowers the
block temperature when the Alarm Panel is “Unset”) and "Extreme" (the block is not
heated when the Alarm Panel is “Unset”). For more information see the separate manual
section 5.2 on “Energy Saving Mode”
Siren Loudness
0
Sets the audio output volume from 0-5
Siren Frequency
1000Hz
Sets the audio output frequency from 1000 to 5000Hz in 500Hz intervals.
Temperature PCB
25
o
C
Set the PCB temperature at which the onboard fan will operate (where fitted). 10-40
o
C in
1
o
increments.