The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed
as follows: select blinking LED no. 8 and press SET 3 times. The LED will
start blinking alternately 1 1 1 0 1 1 1 0 1 1 1 0. This means there is a
period of 30 seconds to select the functions in Extended Menu 3 using the
SEL and SET keys and then, after a further 30 seconds, the control unit will
revert to the main menu.
DECELERATION FORCE ADJUSTMENT:
Operator force during the deceleration stage can be programmed on the
control unit.
You can select one of 6 different power levels as follows; ensure you have
enabled Extended Menu 3; each combination of lit LEDs defines a level as
shown in the above table; in practice, starting from the bottom LED (LED
1) and proceeding upward, each additional LED corresponds to a higher
power level. Use the SEL key to scroll through the different power levels;
for each selected power level the top LED will blink (for example, selecting
level 4, LED 1 + LED 2 + LED 3 will be steady on, while LED 4 will blink);
press SET to confirm.
Factory setting: level 3 selected.
RESET
If it becomes necessary to reset the control unit to restore the factory
settings, press the SELECT and SET keys together; this will cause all the
RED indicator LEDs to light simultaneously followed immediately by the
control unit switching off.
DIAGNOSTICS
Photocell Test:
The control unit is prearranged for connection of safety devices in
compliance with standard EN 12453 point 5.1.1.6. At each operating
cycle a functional test of the connected photocell is performed. In the case
of an open circuit and/or malfunctioning of the photocell, the control unit
does not enable movement of the gate and visually signals the test failed
condition by causing all the indicator LEDs to blink simultaneously. As soon
as correct operation of the photocell is restored, the control unit is ready
for normal use. This operating mode guarantees failure mode monitoring in
compliance with EN 954-1 Category 2.
Commands input test:
IIn correspondence with each low voltage command input, the control unit
is equipped with an indicator LED so that the status of the input can be
checked at a glance.
Operating logic: LED on input closed, LED off input open.
EXTENDED MENU 3
level
L1
1
LED 1
L2
2
LED 1 +LED 2
L3
3
LED 1 +LED 2 +LED 3
L4
4
LED 1 + LED 2 +LED 3 +LED 4
L5
5
LED 1 + LED 2 +LED 3 +LED 4 +LED 5
L6
6
LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6
L7
7
LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6 + LED 7
LEV
MENU
3 FLASHES