7.3 DIP-SWITCHES AND TRIMMERS ADJUSMENTS
Important
Note:
change the settings of dip-switches SW1 and SW2 with the control unit off and only subsequently repeat the control unit
programming procedure.
7.3.1 MOTOR 1 OR MOTOR 2 DELAY CONTROL AND ENABLING OF 1 OR 2 MOTORS
1
1
ON
2
MOTOR
NOT
CONSID.
2
MOTORS
MOTOR
2 DELAY
2
MOTORS
MOTOR
1 DELAY
1
ON
2
1
ON
2
SW1
SW1
SW1
Important note:
in the case of 1 motor operation (Dip Switch 1 of SW1 set in OFF position), Dip Switch 2 of SW1 must be set in OFF
position, otherwise SW2 is disabled.
The electronic control unit is equipped with a dip-switch SW1 that is used to select operation with 1 or 2 motors and to define which of the
two starts first and which starts second.
7.3.2 MOTOR 1 AND MOTOR 2 STROKE DIRECTION
INV
OFF
INV
OFF
INV
MOT 1
INV
OFF
INV
OFF
INV
MOT 2
INV
MOT 1
INV
MOT 2
1
ON
2
1
ON
2
1
ON
2
1
ON
2
SW2
SW2
SW2
SW2
The electronic control unit is equipped with dip-switches that can be used to change the stroke direction of each connected motor without rewiring
the electrical connections: dip-switch 1 controls Motor 1 while dip-switch 2 controls Motor 2.
7.3.3. DECELERATION (SLOWING):
The motors deceleration function is used on gates to prevent the moving leaves from slamming at speed into the limit stops at the end of the
opening and closing strokes.
During Motor Time programming the control unit allows programming of deceleration in the required points (immediately before full opening and
full closing); in addition, using the “SLOWING” trimmer the force intensity can be adjusted during the deceleration phase in three fine adjustment
level settings.
7.3.4. MOTOR SPEED ADJUSTMENT (SPEED):
The electronic control unit is equipped with a “SPEED” trimmer for adjustment of the speed delivered by the Motors, completely managed by
the microprocessor.
Adjustment can be performed in a range between 50% and 100% of maximum speed.
Initial starting torque can be set for each movement by feeding the operator at full power for 2 seconds, even if operator speed control is
enabled.
Important notes:
- Initial starting torque is disabled automatically if the Soft Start function is enabled;
- If the “FORCE” trimmer is adjusted, the self-learning procedure must be repeated because the movement and deceleration times may
change.
7.3.5. OBSTACLE DETECTION (SENS):
The electronic control unit is equipped with a
“SENS”
trimmer, completely managed by the microprocessor, for adjustment of the opposing
Force required to detect the presence of an obstacle. The adjustment can be made with a trip time from a minimum of 0.1 seconds to a
maximum of 10 seconds
ATTENTION:
with the sensitivity set at the minimum level, it is recommended to install a safety edge.
Important notes:
- the detection of the obstacle causes the brief reversal of the motion during closing and opening.
- In the absence of limit switches connected to the control unit the detection of the obstacle always causes the brief inversion of the