52
COMUNELLO
®Copyright 2021 - All rights reserved
• Press the SET key;
• LED L6 becomes steady on and programming will be completed.
If you wish to enable “3 Minutes Timed” operation, repeat the operation described above; pressing the SELECT key twice (LED L6 will blink
rapidly), rather than once, and then pushing SET key. Repeat the procedure if you wish to restore the initial configuration.
8.3.7.
LED L7
- REMOTE RADIO CONTROL PROGRAMMING:
The control unit allows the transmission code to be programmed remotely without acting directly on the control unit SELECT key.
Remote programming of a Radio remote control is performed as follows:
• Send, continuously for a time in excess of 10 seconds, the code of a previously saved remote control;
• the control unit thus enters programming mode as described in the main menu (see sec. 9.1.2).
• If a previously saved pedestrian code is transmitted continuously the control unit will enter programming mode of a new pedestrian
code and LED L2 will blink as though acquisition of the pedestrian code were active (1 1 0 1 1 0 1 1 0);
• If the code is associated with the 2nd CH/AUX input the LED will blink as though acquisition of the 2nd CH code were active (1 1
1 0 1 1 1 0 1 1 1 0).
To enable the remote programming function, proceed as follows:
• Make sure you have enabled the extended Menu 2 (as shown by the alternate flashing 1 1 0 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L7;
• Press the SET key;
• LED L7 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the initial configuration.
8.4 EXTENDED MENU 3
The control unit is factory set to allow direct selection exclusively of the main menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed as follows:
• Select blinking LEV LED;
• press SET 3 times;
• The led will start blinking (alternate flashing of the LEV LED
).
There will be 30 seconds to select the functions of the
Extended Menu 3
using the SELECT and SET keys; once an additional 30 seconds
have elapsed the control unit reverts to the main menu.
ID
REFERENCE LED
L1
SOFT STOP
ON
OFF
L2
SOFT START
ON
OFF
L3
RELEASE STROKE
ON
OFF
L4
SLAM LOCK
ON
OFF
L5
ELS / CMD PED
ON
OFF
L6
LAMP / L.CORT / INDICATOR L
ON
OFF
L7
PRELAMP / LAMP IN PAUSE
ON
OFF
LEV
LIVEL
3 FLASHING
8.4.1.
LED L1
- SOFT STOP:
The control unit is supplied by the manufacturer with the Soft Stop function disabled. To enable the function, proceed as follows:
• Make sure you have enabled the extended Menu 3 (as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L1;
• Press the SET key;
• LED L1 becomes steady on and programming will be completed.
In this way, the control unit will reduce the speed to zero gradually (within 2 seconds) at the end of the door stroke, when an intermediate
STOP command or a reverse command is sent.
Rep
eat the procedure if
you wish to restore the previous configuration.
Notes:
- Soft-stop does not act when a limit-switch is intercepted, when the Stop button/safety edge is activated and in the event of an obstacle.
8.4.2.
LED L2
- SOFT START:
The control unit is supplied by factory with the Soft Start function disabled. With this function enabled at the beginning of the movement the
speed gradually increase from the minimum to the value set by the “SPEED” trimmer during the first 2 seconds of operation.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 3 (as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L2;
• LED L2 becomes steady on and programming will be completed.