ENGLISH
43
COMUNELLO
®Copyright 2021 - All rights reserved
7 DETAILED DESCRIPTION OF ALL FUNCTIONS
7.1 ELECTRICAL CONNECTIONS
CN1:
BATT+24V:
Back-up B input
BATT-24V:
Back-up Battery – input
LAMP+24V:
25W Flashing Light + output
LAMP-24V:
25W Flashing Light – output
MOT1+:
Motor 1 + Output.
MOT1-:
Motor 1 – Output
MOT2+:
Motor 2 + Output
MOT2-:
Motor 2 – Output
ELS+:
Electric lock +24Vdc
ELS-:
Electric lock -
CN2:
2nd CH:
Aux Radio CH Output (Free Contact max load 30V 1A)
2nd CH:
Aux Radio CH Output (Free Contact max load 30V 1A)
FOTO +:
Photocell control and power supply
FOTO -:
Common GND input
DS2:
Safety device 2 input (N.C.)
GND:
Common GND input
DS1:
Safety device 1 input (N.C.)
STOP 8K2:
STOP Input / 8K2
GND:
Common GND input
P PED:
Pedestrian Pushbutton/Single Leaf/open input (N.O.)
PP:
Open-close/close command Pushbutton input (N.O.).
ELS+:
Electric lock +24Vdc
ELS-:
Electric lock -
24V 5W:
Services output (+ 24Vdc)
GND:
Common GND input
+24V LED:
Indicator light output (+24 V 4 W)
ANT-:
Antenna Ground Input.
ANT+:
Antenna Hot pole Input.
CN3:
ENC1 +:
Motor 1 Encoder Power Input
ENC1 E:
Motor 1 Encoder Signal Input
GND:
Common GND input
MOT1 FCA:
Motor 1 Opening Limit Switch Input (N.C.)
MOT1 FCC:
Motor 1 Closing Limit Switch Input (N.C.)
ENC2 +:
Motor 2 Encoder Power Input”
ENC2 E:
Motor 2 Encoder Signal Input
ENC2 GND:
Motor GND input
MOT2 FCA:
Motor 2 Opening Limit Switch Input (N.C.)
MOT2 FCC:
Motor 2 Closing Limit Switch Input (N.C.)
CN4:
Secondary transformer
CN5:
Primary transformer
CN8:
L:
230 V line input (phase)
N:
230 V line input (neutral)
7.2 FUNCTIONAL CHARACTERISTICS
7.2.1 AUTOMATIC OPERATION (OPEN/CLOSE):
When either a stored remote or the connected low voltage pushbutton panel is used to control the gate, operation is as follows: the first
command opens the gate until motor time elapses or until the gate reaches its opening limit position; the second command closes the
gate; if another command is transmitted before motor time has elapsed or before one of the two limiters has been reached, the control unit
reverses the movement direction during both opening and closing.
7.2.2 STEP-BY-STEP OPERATION:
When the LED L1 of the main menu is turned on, when either the remote or the low voltage control pushbuttons are used to control the
gate, operation is as follows: the first command opens the gate until motor time or until the gate reaches its opening limit position; the
second command closes the gate; if another command is transmitted before motor time has elapsed or before one of the limit stops has
been reached, the control unit stops the movement. Another command causes the gate to start moving again in the opposite direction.
7.2.3 STEP-BY-STEP 1 OPERATION:
Using either the remote control ( LED No. 1 on ) or the low voltage buttons to operate the gate, the following operation will be effected: the
first command opens the gate until the motor limit time expires or until the gate reaches its opening limit. The second command closes the
gate; if a command is sent before the end of the motor limit time or when one of the two limit switches is reached, the control unit always
Summary of Contents for QUAD-24V-HP
Page 27: ...55 COMUNELLO Copyright 2021 All rights reserved NOTES ...
Page 106: ...NOTES ...
Page 107: ...NOTES ...
Page 133: ...159 COMUNELLO Copyright 2021 All rights reserved NOTES ...