APPENDIX A
T H I S D O C U M E N T I S T H E P R O P E R T Y O F X I C O M T E C H N O LO G Y . R E P R O D U C T I O N O R R E LE AS E WI T H O U T E XP R E S S P E R M I S S I O N I S S T R I C T LY P R O HI B I T E D.
XTD-400C, 5.85 – 6.425 GHz, RO1
Document No. 305-0386-201
REV 2
Page 10 of 11
Spec
Paragraph
No
Test Description
Test Condition
Requirements
Units
Measured
Performance
Pass
or
Fail
Min
Max
3.1.1 &
3.1.4.1
3.1.4.1.2
3.1.4.1.3
Spurious Signals
Note 3.
-37 dBc max
10 to 10,000 Hz
(-20(1.5 + log(f)) +13) dBc
max
10-100 kHz
-60 dBc max
>100 kHz
Power Line Related:
–50 dBc max
line related individual
-47 dBc max
sum of all
STD
Freq = 6.1375 GHz
V
in
= 100 VAC
P
o
= 50.4 dBm
Span = 2 KHz
N/A
Note
3
dBc
See attached
plot
Pass
Fail
Span = 20 KHz
N/A
Note
3
dBc
See attached
plot
Pass
Fail
Span = 200 KHz
N/A
Note
3
dBc
See attached
plot
Pass
Fail
Span = 2 MHz
N/A
Note
3
dBc
See attached
plot
Pass
Fail
Span = 20 MHz
N/A
Note
3
dBc
See attached
plot
Pass
Fail
Span = 200 MHz
N/A
Note
3
dBc
See attached
plot
Pass
Fail
3.1.1 &
3.1.14.4
Out of Band Spurious
LO+2IF = 6.8 GHz
STD
Freq. = 5.85 GHz
V
in
= 100 VAC
P
o
= P
rated
– 3 dB
N/A
-60
dBc
See attached
plot
Pass
Fail
Freq = 3.625 to 4.200
GHz
N/A
-60
dBc
See attached
plot
Pass
Fail
* referenced to measured small signal gain across the band
EAR EXPORT CONTROLLED: The information contained in this Manual refers or relates to a product that is subject
to the U.S. Export Administration Regulations (EAR). Transfer of data herein by any means to a Foreign Person,
whether in the U.S. or abroad, may require an export license from the U.S. Department of Commerce.