![Comtech EF Data Radyne RCS20 Installation And Operation Manual Download Page 46](http://html1.mh-extra.com/html/comtech-ef-data/radyne-rcs20/radyne-rcs20_installation-and-operation-manual_2648530046.webp)
RCS20 M:N Redundancy Switch
Revision 15
User Interfaces
MN-RCS20 and CD-RCS20
4–14
Key
Label
Function
S4
RETURN Pressed to return to the Backup Mode Configuration Screen.
Numeric Keypad ---
Press <CLR> or <RETURN> to abort programming (no switch parameters changed).
Returns to the Backup Mode Configuration Screen.
4.3.1.8
BACKUP MODE 2 SELECT
This screen allows the user to select the mode of backup operation for Backup Channel 2 (Prime Channel
9), if this channel is configured as a backup channel. The following backup modes are available:
•
Manual - allows the operator to force backups to occur even if prime channel modems have not
failed.
•
Non-Revertive - allows automatic backups to occur when prime channels fail, but once a channel
is backed up, it will remain backed up until manually reset by the operator.
•
Revertive - allows automatic backups to occur when prime channels fail, and after a channel is
backed up, if the prime channel clears its error, the backup can become available for another
prime channel.
4.3.1.8.1
Programming steps:
1.
Press <MANUAL> to configure Backup Channel 2 for manual operation. The switch parameter
table will be updated immediately.
2.
Press <NON-REV> to configure Backup Channel 2 for automatic non-revertive operation. The
switch parameter table will be updated immediately.
3.
Press <REVERT> to configure Backup Channel 2 for automatic revertive operation. The switch
parameter table will be updated immediately.
4.
Press <CLR> or <RETURN> to abort programming (no switch parameters changed). The display
will return to Config Switch Screen 4 (Backup Mode Configuration).
<BACKUP> MODE CONFIGURATION
BACKUP 2 <BACKUP> MODE: MANUAL
<MANUAL> <NON-REV> <REVERT> <RETURN>