![Comtech EF Data Radyne RCS20 Installation And Operation Manual Download Page 137](http://html1.mh-extra.com/html/comtech-ef-data/radyne-rcs20/radyne-rcs20_installation-and-operation-manual_2648530137.webp)
RCS20 M:N Redundancy Switch
Revision 15
Technical Specifications
MN-RCS20 and CD-RCS20
7–1
Chapter 7.
Technical Specifications
7.1
General Specifications
Configurations:
1:9, 2:8, 1:4/1:4, 1:2/1:6, 1:3/1:5
Online Modulators:
1 to 9
Online Demodulators:
1 to 9
Backup Modulators:
1 to 2
Backup Demodulators:
1 to 2
Uplink Transponders:
1 to 9
Downlink Transponders:
1 to 9
Modes of Operation:
Manual, Automatic Revertive,
Automatic Non-Revertive and Pre-emptive
Modulator Switch Time:
250 ms Maximum (Hot-Standby),
2 sec Maximum (No Hot-Standby)
Demodulator Switch Time:
250 ms Maximum (Hot-Standby),
2 sec M Demod Lock Time (No Hot-Standby)
Modulator Switch Delay Time:
0.0 sec to 299.9 sec, 0.1 sec Intervals
Demodulator Switch Delay Time:
0.0 sec to 299.9 sec, 0.1 sec Intervals
7.2
IFS20 (70/140 MHz)
Uplink Transponders:
1 to 9
Downlink Transponders:
1 to 9
Return Loss:
20 dB Minimum
Tx Insertion Loss:
1 dB Nominal
Rx Insertion Loss:
3.5 dB Nominal
IF Connection:
Coaxial, 75 Ohm (50 Ohm Optional)