DM240XR High-Speed Digital Modulator
User Interfaces
MN-DM240XR– Revision 12
4–16
Backup Row FEC packets must arrive on Prime UDP
port + 4
SOURCE IP ADDR: {XXX.XXX.XXX.XXX}
This menu is displayed in Multicast mode only: The user can specify a
source IP address for the backup to listen to. When a non-zero IP address is
entered, the backup will only accept multicast packets addressed to it on its
backup port from the specified source. When an IP address of zero is
entered, the backup will accept multicast packets addressed to it on its
backup port from any source.
In Unicast mode: This field is hidden and has no affect.
The prime accepts Unicast packets addressed to it from
any source.
TERR MAC ADDR: {0123456789AB}
This menu displays the MAC address of the Ethernet Data
Interface card. Entering any non-zero value in this field will
cause the EDI to use the entered value as its MAC address.
Entering a value of all zeros will cause the Ethernet Data
Interface to revert back to its original MAC address.
MONITOR MENU -
The following status monitoring menus are available under the Monitor menu
when the Ethernet Data interface is installed.
TERR ETHERNET -
Scroll down for the Ethernet specific status
LINK STATUS
{Down, Unresolved, 10 Mbps Half, 100 Mbps Half, 10 Mbps
Full, 100Mbps Full, 1 Gbps Half, 1Gbps Full}
This menu displays the current terrestrial link status and rate at
which the Ethernet Data Interface has established a physical
connection.
Down:
The unit is unable to establish a valid link. An
unplugged cable would be one cause of this condition.
Unresolved: Unable to agree on connection speed
10 Mbps Half:
The units has established a valid 10 Mbps Half
Duplex link
100 Mbps Half:
The units has established a valid 100 Mbps
Half Duplex link
10 Mbps Full:
The unit has established a valid 10 Mbps Full
Duplex link
IMPORTANT
Summary of Contents for Radyne DM240XR
Page 2: ......
Page 4: ......
Page 23: ...Errata C for MN DM240XR Rev 12 ER DM240XR EC12 Blank Page ...
Page 34: ...Table of Contents Revision 12 DM240XR High Speed Digital Modulator MN DM240XR viii Notes ...
Page 46: ...DM240XR High Speed Digital Modulator Installation MN DM240XR Revision 12 2 4 Notes ...
Page 96: ...DM240XR High Speed Digital Modulator User Interfaces MN DM240XR Revision 12 4 48 Notes ...
Page 200: ...DM240XR High Speed Digital Modulator TCP IP Ethernet Setup MN DM240XR Revision 12 B 8 Notes ...
Page 222: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...