DM240XR High-Speed Digital Modulator
TCP/IP Ethernet Setup
MN-DM240XR– Revision 12
B–3
set to a foreign address. Broadcast and loop back addresses will not be allowed. Router not used
example: Router IP Address setting: 010.000.001.001.
8.
MODEM EADDR
: This displays the Modem (Unit) Ethernet Address. The Modem Ethernet
Address is configured at the factory. It is a unique Radyne equipment identifier Address.
Example: 0010650903EB
9.
ETHER RATE
: This displays the current Ethernet port data rate. If multiple rates are available,
then a selection can be made to specify the Ethernet port data rate (10BaseT). Example Ethernet
port Data Rate: 10 MBPS/HD
B.3
Network Configuration Summary
If the above steps were followed and the information was entered, then the following would be
the TCP / IP configuration summary for a ‘no router specified’ setup:
1.
Boot Mode =
NON-VOL
2.
Bootp Server Tag =
206
3.
Modem Host=
DM240
4.
IP Address Mask =
255.255.0.0
5.
Modem IP Address =
172.18.100.215
6.
Server IP Address =
172.18.4.250
7.
Router IP Address =
010.000.001.001
8.
Modem Ethernet Address= 0010650903EB
9.
Ethernet Rate =
10 MBPS/HD
B.4
Ethernet Test
B.4.1
Connecting the Modem Ethernet Cable to a Network Link
1.
Connect the Network Switch (Hub) to the Modem Ethernet port (J9) using standard RJ-45
to RJ-45 10BaseT (CAT-5) Cables as shown below.
DM240 Ethernet Network Connection
B.4.2
Connecting the Modem Ethernet Cable Directly to a Computer (without a
Network)
The user can directly connect to the equipment without connecting to a network. This will often
occur at remote sites where a network is not available. To connect, the user will need an Ethernet
Crossover (Null) cable. The pinout for this cable is as follows,
Summary of Contents for Radyne DM240XR
Page 2: ......
Page 4: ......
Page 23: ...Errata C for MN DM240XR Rev 12 ER DM240XR EC12 Blank Page ...
Page 34: ...Table of Contents Revision 12 DM240XR High Speed Digital Modulator MN DM240XR viii Notes ...
Page 46: ...DM240XR High Speed Digital Modulator Installation MN DM240XR Revision 12 2 4 Notes ...
Page 96: ...DM240XR High Speed Digital Modulator User Interfaces MN DM240XR Revision 12 4 48 Notes ...
Page 200: ...DM240XR High Speed Digital Modulator TCP IP Ethernet Setup MN DM240XR Revision 12 B 8 Notes ...
Page 222: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...