MN-DM240XR– Revision 12
B–1
Appendix B.
TCP/IP Ethernet Setup
B.1
Introduction
The DM240XR supports SNMP, FTP protocols and the Web Browser. Utilization of the
protocols is dependent upon proper set up of the TCP-IP menus. This document is to be used
only as a guideline for setting up the TCP-IP menus. Contact the IT manager for proper guidance
to ensure setup is successful. For additional information on the various WEB or SNMP
configurations and descriptions refer to Section 8 and 10.
B.2
TCP/IP Network Configuration
Using the Front Panel display and arrow keys, scroll thru the System menu until the TCP / IP sub
menu is displayed. Each unit requires proper configuration with the correct network settings.
Contact the IT manager for a valid IP address mask, Modem, server and router IP addresses.
Enter into the TCP / IP menu and the following Sub menus will appear, however the order may
vary.
1.
Boot Mode
: This allows for the selection of the operating boot mode for the TCP / IP.
Several selections are available and are described below. When configuring the modem for
Web Browser, Boot Mode must be set to “NON-VOL”. A brief description of the available
selections are:
a.
Default
: If the Ethernet interface is not to be used, select this mode. No IP Address or
mask changes will be allowed while in this mode of operation. The following parameters
will be set and will not change until the boot mode is changed. The IP addresses are non
accessible addresses:
IP MASK
255.000.000.000
MODEM IP ADDR
010.000.000.001
SERVER IP ADDR
010.001.001.001
ROUTER IP ADDR
010.000.001.001
b.
BOOTp
: When enabled, at boot time, the modem will use the Bootp Protocol to
automatically get names, masks, and IP Addresses of the modem, router, and server from
the Network Manager. This should be consistent with the tag expected by the users
Bootp Server (see the next menu selection for setting the BOOTp TAG). If Bootp is not
enabled, the modem will ignore the BOOTp Tag setting.
Summary of Contents for Radyne DM240XR
Page 2: ......
Page 4: ......
Page 23: ...Errata C for MN DM240XR Rev 12 ER DM240XR EC12 Blank Page ...
Page 34: ...Table of Contents Revision 12 DM240XR High Speed Digital Modulator MN DM240XR viii Notes ...
Page 46: ...DM240XR High Speed Digital Modulator Installation MN DM240XR Revision 12 2 4 Notes ...
Page 96: ...DM240XR High Speed Digital Modulator User Interfaces MN DM240XR Revision 12 4 48 Notes ...
Page 200: ...DM240XR High Speed Digital Modulator TCP IP Ethernet Setup MN DM240XR Revision 12 B 8 Notes ...
Page 222: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...