DM240XR High-Speed Digital Modulator
Remote Operations
MN-DM240XR– Revision 12
9–19
<1> Redundancy
Mode
0 = Force Prime,
1 = Force Backup,
2 = Manual Revert,
3 = Auto-Revert
<1>
Prime PIIC Slot
1 – 3
<1> Backup
PIIC
Slot
1 – 3
<1>
Pilot Symbols
0 = Off, 1= On
<1> Inner
FEC
Bypass
0 = Normal, 1 = Bypass
<1> PL
Scrambler
Bypass
0 = Normal, 1 = Bypass
<1>
Reserved
Set to 0
<1>
Reserved
Set to 1
<2>
Reserved
Set to 0
<4>
Gold Code Seq
Index
0 to 262142
<1>
Sat Framing
3=DVB-S, 5=DTV, 10=DVB-S2 Normal, 15=DVB-S2 Short
<1> Auto
EQ
Enable
0=Off, 1=On
<9>
Auto EQ Filter
Coef Name
8-character NULL terminated string, this is the filter’s name
as shown on the front panel (identical to the filter’s base
filename, the extension is assumed to be “AEQ”)
DM240XR Clock Source Selection Matrix
Interface Type
InClk Source
OutClk Source
RS-422 Serial
SCT or SCTE
SCT Only
G.703 (E3, T3, STS-1)
SCTE Only
SCT, SCTE, or None
HSSI
SCT or SCTE
SCT Only
OC3 SCTE
Only
None
STM-1 SCTE
Only
None
ASI, Advanced ASI
SCTE Only
None
M2P Parallel
SCT or SCTE
SCT Only
DVB Parallel
SCTE Only
SCT Only
Summary of Contents for Radyne DM240XR
Page 2: ......
Page 4: ......
Page 23: ...Errata C for MN DM240XR Rev 12 ER DM240XR EC12 Blank Page ...
Page 34: ...Table of Contents Revision 12 DM240XR High Speed Digital Modulator MN DM240XR viii Notes ...
Page 46: ...DM240XR High Speed Digital Modulator Installation MN DM240XR Revision 12 2 4 Notes ...
Page 96: ...DM240XR High Speed Digital Modulator User Interfaces MN DM240XR Revision 12 4 48 Notes ...
Page 200: ...DM240XR High Speed Digital Modulator TCP IP Ethernet Setup MN DM240XR Revision 12 B 8 Notes ...
Page 222: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...