Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation
5–26
MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command
Query
Response to
Command
Response
to Query
Maximum
Operating Point
N/A
MOP?
272 bytes
Query only.
Returns the maximum operating point of the unit along with its timestamp in the
reply format:
MAXFET=sYYYC mmddyy hhmmss{CR}
MINFET=sYYYC mmddyy hhmmss{CR}
MAXPFT=sYYYC mmddyy hhmmss{CR}
MAXDTP=sYYYC mmddyy hhmmss{CR}
MAXHTS=sYYYC mmddyy hhmmss{CR}
MINHTS=sYYYC mmddyy hhmmss{CR}
MAXOST=sYYYC mmddyy hhmmss{CR}
MAXRFP=sZZ.ZZ mmddyy hhmmss{CR}
MINRFP=sZZ.ZZ mmddyy hhmmss{CR}
Where:
sYYYC is the temperature
sZZ.ZZ is the power
NOTE: Not all LPODs have outside temperature monitor. In which case MAXOST
and MINOST report XXXXX XXXXXX XXXXXX
EXAMPLE: <0001/MOP?{CR}
>0001/mop={CR}
000C 010208 180729{CR}
000C 010208 180729{CR}
000C 010208 180659{CR}
000C 010208 180729{CR}
050C 010208 180729{CR}
050C 010208 180729{CR}
MAXOST=XXXXX XXXXXX XXXXXX{CR}
MINOST=XXXXX XXXXXX XXXXXX{CR}
00.00 010208 180659{CR}
00.00 010208 180659{CR}
MOP=