![Comtech EF Data KST-2000L Installation And Operation Manual Download Page 70](http://html1.mh-extra.com/html/comtech-ef-data/kst-2000l/kst-2000l_installation-and-operation-manual_2648543070.webp)
Satellite Terminal System
Revision 2
Terminal Mode Commands
MN/KST2000L.IOM
7.5 LNB
Commands
Commands and responses to control and to determine the status of an LNB.
LNB
Power Enable
Command
Response
Status
Response
<add/LPE_xxx'cr'
>add/LPE_xxx’cr''lf']
<add/LPE_ 'cr'
>add/LPE_xxx’cr''lf']
Where xxx = ON/OFF, default is OFF
LNB
Calibration
Command
Response
<add/CLNAB_'cr'
>add/CLNAB_'’cr''lf']
Calibration to allow system to determine nominal LNB power
consumption, performed at initial installation only
LNB
Fault
Enable
Command
Response
Status
Response
<add/LFE_xxx'cr'
>add/LFE_xxx'cr''lf']
<add/LFE_'cr'
>add/LFE_xxx'cr''lf']
Where xxx= ON/OFF, default is ON
Determines if the system takes action on LNA fault notification
Select Receive
Band
Command
Response
Status
Response
<add/SRB_n'cr'
>add/SRB_n'cr''lf']
<add/SRB_'cr'
>add/SRB_n'cr''lf']
Where n = A for 10.95 to 11.70 GHz
B for 11.70 to 12.20 GHz
C for 12.25 to 12.75 GHz
7.6 System Communications Commands
Commands and responses for setting up communications with the system.
Address
Select
Command
Response
Status
Response
<add/AS_xxx'cr'
>add/AS_xxx'cr''lf']
<add/AS_'cr'
>add/AS_xxx'cr''lf']
Where add = present address and xxx = new address, 1 to 255
(default = 1)
Baud Rate
Select
Command
Response
Status
Response
<add/BR_xxx'cr'
>add/BR_xxx'cr''lf']
<add/BR_'cr'
>add/BR_xxx'cr''lf']
Where xxx = 300, 600, 1200, 2400, 4800, 9600 or 19200 (default
= 9600)
Parity
Select
Command
Response
Status
Response
<add/PS_xxx'cr'
>add/PS_xxx'cr''lf']
<add/PS_'cr'
>add/PS_xxx'cr''lf']
Where xxx = OD (odd), EV (even) or NO (none – 8 bit), default =
EV